OBJECTIVES: Epicardial adipose tissue (EAT) is a proposed marker of cardiovascular risk; however, clinical application may be limited by variability in post-processing software platforms. We assessed inter-vendor agreement of EAT volume (EATv) and attenuation on both contrast-enhanced (CE) and non-contrast CT (NCT) using a standard coronary CT reporting software (Vitrea), an EAT research-specific software (QFAT) and a freeware imaging software (OsiriX). METHODS: Seventy-six consecutive patients undergoing simultaneous CE and NCT had complete volumetric EAT measurement. Between-software, within-software NCT vs. CE, and inter- and intra-observer agreement were evaluated with analysis by ANOVA (with post hoc adjustment), Bland-Altman with 95% levels of agreement (LoA) and intraclass correlation coefficient (ICC). RESULTS: Mean EATv (freeware 53 ± 31 mL vs. research 93 ± 43 mL vs. coronary 157 ± 64 mL) and attenuation (freeware - 72 ± 25 HU vs. research - 75 ± 3 HU vs. coronary - 61 ± 10 HU) were significantly different between all vendors (ANOVA p < 0.001). EATv was consistently higher in NCT vs. CE for all software packages, with most reproducibility found in research software (bias 26 mL, 95% LoA: 2 to 56 mL), compared to freeware (bias 11 mL 95% LoA: - 46 mL to 69 mL) and coronary software (bias 10 mL 95% LoA: - 127 to 147 mL). Research software had more comparable NCT vs. CE attenuation (- 75 vs. - 72 HU) compared to freeware (- 72 vs. - 57 HU) and coronary (- 61 vs. - 39 HU). Excellent inter-observer agreement was seen with research (ICC 0.98) compared to freeware (ICC 0.73) and coronary software (ICC 0.75) with narrow LoA on Bland-Altman analysis. CONCLUSION: There are significant inter-vendor differences in EAT assessment. Our study suggests that research-specific software has better agreement and reproducibility compared to freeware or coronary software platforms. KEY POINTS: ⢠There are significant differences between EAT volume and attenuation values between software platforms, regardless of scan type. ⢠Non-contrast scans routinely have higher mean EAT volume and attenuation; however, this finding is only consistently seen with research-specific software. ⢠Of the three analyzed packages, research-specific software demonstrates the highest reproducibility, agreement, and reliability for both inter-scan and inter-observer agreement.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Doença da Artéria Coronariana
/
Tomografia Computadorizada por Raios X
Idioma:
En
Ano de publicação:
2023
Tipo de documento:
Article