Your browser doesn't support javascript.
loading
A computational study of the effects of size, location, and number of tears on haemodynamics in surgically repaired type A aortic dissection.
Motoki, Kyosuke; Zhu, Yu; Mirsadraee, Saeed; Rosendahl, Ulrich; Pepper, John; Xu, Xiao Yun.
Afiliação
  • Motoki K; Department of Chemical Engineering, Imperial College London, London, United Kingdom.
  • Zhu Y; Department of Chemical Engineering, Imperial College London, London, United Kingdom.
  • Mirsadraee S; National Heart and Lung Institute, Imperial College London, London, United Kingdom.
  • Rosendahl U; Department of Radiology, Royal Brompton and Harefield Hospitals, London, United Kingdom.
  • Pepper J; National Heart and Lung Institute, Imperial College London, London, United Kingdom.
  • Xu XY; Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals, London, United Kingdom.
Front Cardiovasc Med ; 10: 1215720, 2023.
Article em En | MEDLINE | ID: mdl-37388636
ABSTRACT

Objective:

This study aimed to comprehensively examine the roles of size, location, and number of tears in the progression of surgically repaired type A aortic dissection (TAAD) by assessing haemodynamic changes through patient-specific computational fluid dynamic (CFD) simulations.

Methods:

Two patient-specific TAAD geometries with replaced ascending aorta were reconstructed based upon computed 15 tomography (CT) scans, after which 10 hypothetical models (5 per patient) with different tear configurations were artificially created. CFD simulations were performed on all the models under physiologically realistic boundary conditions.

Results:

Our simulation results showed that increasing either the size or number of the re-entry tears reduced the luminal pressure difference (LPD) and maximum time-averaged wall shear stress (TAWSS), as well as areas exposed to abnormally high or low TAWSS values. Models with a large re-entry tear outperformed the others by reducing the maximum LPD by 1.88 mmHg and 7.39 mmHg, for patients 1 and 2, respectively. Moreover, proximally located re-entry tears in the descending aorta were more effective at reducing LPD than distal re-entry tears.

Discussion:

These computational results indicate that the presence of a relatively large re-entry tear in the proximal descending aorta might help stabilize post-surgery aortic growth. This finding has important implications for the management and risk stratification of surgically repaired TAAD patients. Nevertheless, further validation in a large patient cohort is needed.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article