INTRODUCTION:
To guarantee treatment reproducibility and stability, immobilization devices are essential. Additionally, surface-guided radiation therapy (SGRT) serves as an accurate complement to frameless stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) by aiding patient positioning and real-time monitoring, especially when non-coplanar fields are in use. At our institute, we have developed a surface-guided SRS (SG-SRS) workflow that incorporates our innovative open-face mask (OM) and mouth bite (MB) to guarantee a precise and accurate dose delivery.METHODS:
This study included 40 patients, and all patients were divided into closed mask (CM) and open-face mask (OM) groups according to different positioning flow. Cone beam computed tomography (CBCT) scans were performed, and the registration results were recorded before and after the treatment. Then Bland-Altman method was used to analyze the consistency of AlignRT-guided positioning errors and CBCT scanning results in the OM group. The error changes between 31 fractions in one patient were recorded to evaluate the feasibility of monitoring during treatment.RESULTS:
The median of translation error between stages of the AlignRT positioning process was (0.03-0.07) cm, and the median of rotation error was (0.20-0.40)°, which were significantly better than those of the Fraxion positioning process (0.09-0.11) cm and (0.60-0.75)°. The mean bias values between the AlignRT guided positioning errors and CBCT were 0.01 cm, - 0.07 cm, 0.03 cm, - 0.30°, - 0.08° and 0.00°. The 31 inter-fractional errors of a single patient monitored by SGRT were within 0.10 cm and 0.50°.CONCLUSIONS:
The application of the SGRT with an innovative open-face mask and mouth bite device could achieve precision positioning accuracy and stability, and the accuracy of the AlignRT system exhibits excellent constancy with the CBCT gold standard. The non-coplanar radiation field monitoring can provide reliable support for motion management in fractional treatment.Palavras-chave