Your browser doesn't support javascript.
loading
The influence of pterygium on corneal densitometry evaluated using the Oculus Pentacam system.
Zhang, Jing; Zhang, Liyun; Hu, Huiling; Sun, Liangnan; He, Wenling; Zhang, Zhe; Wang, Jiantao; Nie, Danyao; Liu, Xinhua.
Afiliação
  • Zhang J; Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China.
  • Zhang L; Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China.
  • Hu H; Shenzhen Key Laboratory of Ophthalmology, Shenzhen Eye Hospital, Postgraduate Training Base of Jinzhou Medical University, Shenzhen, Guangdong, China.
  • Sun L; Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China.
  • He W; Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China.
  • Zhang Z; Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China.
  • Wang J; Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China.
  • Nie D; Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China.
  • Liu X; Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China.
Front Med (Lausanne) ; 10: 1184318, 2023.
Article em En | MEDLINE | ID: mdl-37396900
ABSTRACT

Purpose:

To assess the effect of pterygium on corneal densitometry (CD) values.

Methods:

One hundred and nine patients (155 eyes) with primary pterygium were divided into a severe pterygium group (79 eyes) and a mild-to-moderate pterygium group (76 eyes) according to pterygium severity. Among them, 63 patients had monocular pterygium; and 25 patients (38 eyes) underwent pterygium excision combined with conjunctival autograft follow-up. A Pentacam anterior segment analyzer was used to obtain the CD values and corneal morphological parameters, including central corneal thickness (CCT), flat-axis keratometry (K1), steep-axis keratometry (K2), corneal astigmatism, irregular astigmatism, and spherical aberration. CD was subdivided into four concentric radial regions based on corneal diameter and three layers according to depth.

Results:

CD values at 0-12 mm of the anterior 120 µm layer, 0-10 mm of the center layer and full thickness, and 2-6 mm of the posterior 60 µm layer were significantly higher in eyes affected by pterygium than in the contralateral unaffected eyes (all P < 0.05). CD values were significantly higher in the severe pterygium group than in the mild to moderate pterygium group (all P < 0.05). Corneal astigmatism, irregular astigmatism, K1, K2, CCT, and spherical aberration correlated with CD values in eyes with pterygium (all P < 0.05). CD values at 6-10, 0-12 mm in the anterior 120 µm layer and full thickness, 10-12 and 0-12 mm in the center layer were significantly decreased 1 month after pterygium surgery compared with those before surgery (all P < 0.05).

Conclusion:

Patients with pterygium had increased CD values, particularly in the anterior and central layers. CD values were correlated with pterygium severity grading and corneal parameters. Pterygium surgery partially reduced the CD values.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article