Your browser doesn't support javascript.
loading
Surface roughness and gloss alteration of polished resin composites with various filler types after simulated toothbrush abrasion.
Yu, Peng; Yang, Su-Ming; Xu, Yong-Xiang; Wang, Xiao-Yan.
Afiliação
  • Yu P; Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology, Beijing, China.
  • Yang SM; National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Beijing, China.
  • Xu YX; National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Beijing, China.
  • Wang XY; First Dental Clinical Division, Peking University School and Hospital of Stomatology, Beijing, China.
J Dent Sci ; 18(3): 1016-1022, 2023 Jul.
Article em En | MEDLINE | ID: mdl-37404657
Background/purpose: Few studies have focused on the influence of simulated toothbrush abrasion on the surface qualities of novel nanofilled and nanohybrid composites. The aim of the study was to evaluate the surface roughness and gloss values of resin-based composite (RBC) materials with various filler types before and after simulated toothbrush abrasion. Materials and methods: One nanofilled (Filtek Z350 XT [FT3]), two nanohybrids (Harmonize [HM] and Clearfil Majesty [CM]) and one microhybrid (Filtek Z250 [FT2]) were evaluated. Twelve specimens of each material were made and polished with silicon carbide sandpapers. Initial surface roughness and gloss values were measured as negative controls. Then, all specimens were subjected to simulated toothbrush abrasion on a custom-made apparatus. After 2000, 4000 and 8000 cycles, the surface roughness and gloss values of all specimens were tested. One additional specimen from each group was selected for scanning electron microscope (SEM) analysis. Results: For FT3, Ra and GU values did not significantly change until after 8000 cycles during the process of toothbrushing (P > 0.05). For HM, CM and FT2, the Ra and GU values significantly decreased after 4000 and 8000 cycles of toothbrush abrasion (P < 0.05). After 8000 cycles of toothbrush abrasion, FT3 presented the lowest surface roughness and highest gloss values of all materials (P < 0.05). SEM images showed that surface textures and irregularities corresponded to the results of surface roughness and gloss. Conclusion: Surface roughness and gloss after simulated toothbrush abrasion were material dependent. Nanofilled resin composite presented the lowest Ra values and highest GU values.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article