Your browser doesn't support javascript.
loading
Vessel Density Features of Optical Coherence Tomography Angiography for Classification of Optic Neuropathies Using Machine Learning.
Jalili, Jalil; Nadimi, Mohadeseh; Jafari, Behzad; Esfandiari, Amirreza; Mojarad, Mohadeseh; Subramanian, Prem S; Aghsaei Fard, Masoud.
Afiliação
  • Jalili J; Biomedical Engineering Unit (JJ, MN), Cardiovascular Disease Research Center, Heshmat Hospital, School of Medicine, Guilan University of Medical Sciences, Rasht, Iran; Farabi Eye Hospital (BJ, AE, MAF), Tehran University of Medical Sciences, Tehran, Iran; School of Medicine (MM), Guilan University of Medical Sciences, Rasht, Iran; and Department of Ophthalmology (PSS), University of Colorado, School of Medicine, Aurora, Colorado.
J Neuroophthalmol ; 44(1): 41-46, 2024 Mar 01.
Article em En | MEDLINE | ID: mdl-37440373
ABSTRACT

BACKGROUND:

To evaluate the classification performance of machine learning based on the 4 vessel density features of peripapillary optical coherence tomography angiography (OCT-A) for classifying healthy, nonarteritic anterior ischemic optic neuropathy (NAION), and optic neuritis (ON) eyes.

METHODS:

Forty-five eyes of 45 NAION patients, 32 eyes of 32 ON patients, and 76 eyes of 76 healthy individuals with optic nerve head OCT-A were included. Four vessel density features of OCT-A images were developed using a threshold-based segmentation method and were integrated in 3 models of machine learning classifiers. Classification performances of support vector machine (SVM), random forest, and Gaussian Naive Bayes (GNB) models were evaluated with the area under the receiver-operating-characteristic curve (AUC) and accuracy.

RESULTS:

We divided 121 images into a 70% training set and 30% test set. For ON-NAION classification, best results were achieved with 50% threshold, in which 3 classifiers (SVM, RF, and GNB) discriminated ON from NAION with an AUC of 1 and accuracy of 1. For ON-Normal classification, with 100% threshold, SVM and RF classifiers were able to discriminate normal from ON with AUCs of 1 and accuracies of 1. For NAION-normal classification, with 50% threshold, the SVM and RF classified the NAION from normal with AUC and accuracy of 1.

CONCLUSIONS:

ML based on the combined peripapillary vessel density features of total vessels and capillaries in the whole image and ring image could provide excellent performance for NAION and ON distinction.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Disco Óptico / Neurite Óptica / Neuropatia Óptica Isquêmica Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Disco Óptico / Neurite Óptica / Neuropatia Óptica Isquêmica Idioma: En Ano de publicação: 2024 Tipo de documento: Article