Your browser doesn't support javascript.
loading
Simple and sensitive detection of miRNA-122 based on a micro-biosensor through square wave voltammetry.
Zhai, Jiali; Sun, Huiyuan; Li, Mingkang; Gao, Yuhao; Hu, Yixin; Gao, Zhi; Xie, Xiyu; Zhang, Lixia; Zhao, Guangtao.
Afiliação
  • Zhai J; School of Rehabilitation Medicine of Binzhou Medical University Yantai 264003 China shiyanzhang2007@163.com gtzhao@bzmc.edu.cn +86 535 6913246 +86 535 6913213.
  • Sun H; Department of Critical Care Medicine, Yantai Yuhuangding Hospital Yantai 264003 China.
  • Li M; The 2nd Medical College of Binzhou Medical University Yantai 264003 China.
  • Gao Y; The 2nd Medical College of Binzhou Medical University Yantai 264003 China.
  • Hu Y; The 2nd Medical College of Binzhou Medical University Yantai 264003 China.
  • Gao Z; Academy of Traditional Chinese and Western Medicine of Binzhou Medical University Yantai 264003 China.
  • Xie X; Academy of Traditional Chinese and Western Medicine of Binzhou Medical University Yantai 264003 China.
  • Zhang L; School of Basic Medicine, Binzhou Medical University Yantai 264003 China.
  • Zhao G; School of Basic Medicine, Binzhou Medical University Yantai 264003 China.
RSC Adv ; 13(31): 21414-21420, 2023 Jul 12.
Article em En | MEDLINE | ID: mdl-37465577
The simple and sensitive detection of miRNA-122 in blood is crucially important for early hepatocellular carcinoma (HCC) diagnosis. In this work, a platinum microelectrode (PtµE) was prepared and electrodeposited with molybdenum disulfide (MoS2) and gold nanoparticles (AuNP), respectively, and denoted as PtµE/MoS2/Au. The prepared PtµE/MoS2/Au was used as the microsensor for the detection of miRNA-122 combined with the probe DNA as a biorecognition element which is the complementary strand of miRNA-122. The PtµE/MoS2/Au conjugated with the probe DNA modified with sulfydryl units was used as the micro-biosensor for the detection of miRNA-122. The square wave voltammetry was performed for the quantitative detection of miRNA-122 using [Fe(CN)6]4-/3- as a mediator. Under the optimized conditions, the PtµE/MoS2/Au micro-biosensor shows a linear detection toward miRNA-122 ranging from 10-11 to 10-8 M (S = 6.9 nA dec-1, R2 = 0.9997), and the detection limit is 1.6 × 10-12 M (3σ/b). The PtµE/MoS2/Au micro-biosensor demonstrates good selectivity against other types of proteins and small molecules, and has good reproducibility. Moreover, the PtµE/MoS2/Au micro-biosensor was successfully applied for the measurement of miRNA-122 in real blood samples. Herein, the proposed detection assay could be a potential tool in HCC clinical diagnostics with high sensitivity.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article