Suprascapular nerve injury after reverse total shoulder arthroplasty: correlation with screw out of vault penetration and functional situation: prospective study.
J Shoulder Elbow Surg
; 32(12): 2421-2429, 2023 Dec.
Article
em En
| MEDLINE
| ID: mdl-37499787
ABSTRACT
BACKGROUND:
Baseplate screws have been suggested as a possible cause of suprascapular neuropathy after reverse total shoulder arthroplasty. This study aims to investigate the association between screw penetration out of the vault, electromyographic study, and the clinical outcomes.METHODS:
A total of 31 patients who underwent reverse total shoulder arthroplasty for cuff tear arthropathy were prospectively enrolled. They were followed up for a minimum of 24 months. All patients underwent computed tomography 6 months postoperatively to determine the extraosseous position of the screws (perforation of the second bone cortex and protrusion into the supra- or infraspinatus fossa). Electrodiagnostic evaluation was performed preoperatively and postoperatively to stablish any relation between cortex perforation of the screw and suprascapular nerve (SSN) injury. Clinical outcomes pre- and postoperatively (Constant score, ranges of motion, and visual analog scale) of patients with and without documented injury were recorded.RESULTS:
A total of 14 patients (45.2%) had an abnormal preoperative SSN electrodiagnostic study (chronic or disuse injuries), and 6 patients (19.4%) had an abnormal postoperative study (acute injury). Of the 6 patients, 2 cases appeared over the pre-existing lesion and 4 appeared over an intact preoperative nerve, all of them affecting the infraspinatus branch of the SSN. Perforation of the second cortex was detected for 60% of superior screws and 40% of posterior screws. The mean lengths of the superior and posterior screws were 30 and 18.2 mm, respectively. Patients with screw perforation of the second cortex were assessed as having a high risk of nerve injury (40% vs. 9.5%).CONCLUSIONS:
Preoperative SSN injuries do not have a significant clinical impact and do not predispose to an acute postoperative SSN lesion. The Constant score and visual analog scale score for patients with acute SSN injuries were not statistically different from those without SSN injury. The extraosseous position of the screw increases the probability of an SSN injury to 31%. This risk is higher with the posterior screw, which leads us to question whether it is really necessary to use it.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Articulação do Ombro
/
Traumatismos dos Nervos Periféricos
/
Lesões do Ombro
/
Artroplastia do Ombro
Idioma:
En
Ano de publicação:
2023
Tipo de documento:
Article