Your browser doesn't support javascript.
loading
A New Perspective on SPME and SPME Arrow: Formaldehyde Determination by On-Sample Derivatization Coupled with Multiple and Cooling-Assisted Extractions.
Dugheri, Stefano; Cappelli, Giovanni; Fanfani, Niccolò; Ceccarelli, Jacopo; Marrubini, Giorgio; Squillaci, Donato; Traversini, Veronica; Gori, Riccardo; Mucci, Nicola; Arcangeli, Giulio.
Afiliação
  • Dugheri S; Industrial Hygiene and Toxicology Laboratory, University Hospital Careggi, 50134 Florence, Italy.
  • Cappelli G; Department of Experimental and Clinical Medicine, University of Florence, 50121 Florence, Italy.
  • Fanfani N; Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, 50121 Florence, Italy.
  • Ceccarelli J; Department of Experimental and Clinical Medicine, University of Florence, 50121 Florence, Italy.
  • Marrubini G; Department of Drug Sciences, University of Pavia, 27100 Pavia, Italy.
  • Squillaci D; Department of Experimental and Clinical Medicine, University of Florence, 50121 Florence, Italy.
  • Traversini V; Department of Experimental and Clinical Medicine, University of Florence, 50121 Florence, Italy.
  • Gori R; Department of Civil and Environmental Engineering, University of Florence, 50121 Florence, Italy.
  • Mucci N; Department of Experimental and Clinical Medicine, University of Florence, 50121 Florence, Italy.
  • Arcangeli G; Department of Experimental and Clinical Medicine, University of Florence, 50121 Florence, Italy.
Molecules ; 28(14)2023 Jul 16.
Article em En | MEDLINE | ID: mdl-37513313
ABSTRACT
Formaldehyde (FA) is a toxic compound and a human carcinogen. Regulating FA-releasing substances in commercial goods is a growing and interesting topic worldwide production sectors, like food industries, textiles, wood manufacture, and cosmetics, are involved. Thus, there is a need for sensitive, economical, and specific FA monitoring tools. Solid-phase microextraction (SPME), with O-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine (PFBHA) on-sample derivatization and gas chromatography, is proposed for FA monitoring of real-life samples. This study reports the use of polydimethylsiloxane (PDMS) as a sorbent phase combined with innovative commercial methods, such as multiple SPME (MSPME) and cooling-assisted SPME, for FA determination. Critical steps, such as extraction and sampling, were evaluated in method development. The derivatization was performed at 60 °C for 30 min, followed by 15 min sampling at 10 °C, in three cycles (SPME Arrow) or six cycles (SPME). The sensitivity was satisfactory for the method's purposes (LOD-LOQ at 11-36 ng L-1, and 8-26 ng L-1, for SPME and SPME Arrow, respectively). The method's linearity ranges from the lower LOQ at trace level (ng L-1) to the upper LOQ at 40 mg L-1. The precision range was 5.7-10.2% and 4.8-9.6% and the accuracy was 97.4% and 96.3% for SPME and SPME Arrow, respectively. The cooling MSPME set-up applied to real commercial goods provided results of quality comparable to previously published data.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article