Your browser doesn't support javascript.
loading
Integration of Metal-Organic Polyhedra onto a Nanophotonic Sensor for Real-Time Detection of Nitrogenous Organic Pollutants in Water.
Calvo-Lozano, Olalla; Hernández-López, Laura; Gomez, Leyre; Carné-Sánchez, Arnau; von Baeckmann, Cornelia; Lechuga, Laura M; Maspoch, Daniel.
Afiliação
  • Calvo-Lozano O; Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, CIBER-BNN, and Barcelona Institute of Science and Technology, Campus UAB, 08193 Bellaterra, Barcelona, Spain.
  • Hernández-López L; Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, and Barcelona Institute of Science and Technology, Campus UAB, 08193 Bellaterra, Barcelona, Spain.
  • Gomez L; Departament de Química, Facultat de Ciències, Universitat Autònoma de Barcelona, 08193 Bellaterra, Spain.
  • Carné-Sánchez A; Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, and Barcelona Institute of Science and Technology, Campus UAB, 08193 Bellaterra, Barcelona, Spain.
  • von Baeckmann C; Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, and Barcelona Institute of Science and Technology, Campus UAB, 08193 Bellaterra, Barcelona, Spain.
  • Lechuga LM; Departament de Química, Facultat de Ciències, Universitat Autònoma de Barcelona, 08193 Bellaterra, Spain.
  • Maspoch D; Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, and Barcelona Institute of Science and Technology, Campus UAB, 08193 Bellaterra, Barcelona, Spain.
ACS Appl Mater Interfaces ; 15(33): 39523-39529, 2023 Aug 23.
Article em En | MEDLINE | ID: mdl-37566722
ABSTRACT
The grave health and environmental consequences of water pollution demand new tools, including new sensing technologies, for the immediate detection of contaminants in situ. Herein, we report the integration of metal-organic cages or polyhedra (MOCs/MOPs) within a nanophotonic sensor for the rapid, direct, and real-time detection of small (<500 Da) pollutant molecules in water. The sensor, a bimodal waveguide silicon interferometer incorporating Rh(II)-based MOPs as specific chemical receptors, does not require sample pretreatment and enables minimal expenditure of time and reagents. We validated our sensor for the detection of two common pollutants the industrial corrosion inhibitor 1,2,3-benzotriazole (BTA) and the systemic insecticide imidacloprid (IMD). The sensor offers a fast time-to-result response (15 min), high sensitivity, and high accuracy. The limit of detection (LOD) in tap water for BTA is 0.068 µg/mL and for IMD, 0.107 µg/mL, both of which are below the corresponding toxicity thresholds defined by the European Chemicals Agency (ECHA). By combining innovative chemical molecular receptors such as MOPs with state-of-the-art photonic sensing technologies, our research opens the path to implement competitive sensor devices for in situ environmental monitoring.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article