Your browser doesn't support javascript.
loading
Thiacalix[4]arene-based metal-organic framework/reduced graphene oxide composite for electrochemical detection of chlorogenic acid.
Zhao, Tong; Niu, Xia; Pei, Wen-Yuan; Ma, Jian-Fang.
Afiliação
  • Zhao T; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Department of Chemistry, Northeast Normal University, Changchun, 130024, China.
  • Niu X; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Department of Chemistry, Northeast Normal University, Changchun, 130024, China.
  • Pei WY; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Department of Chemistry, Northeast Normal University, Changchun, 130024, China. Electronic address: peiwy527@nenu.edu.cn.
  • Ma JF; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Department of Chemistry, Northeast Normal University, Changchun, 130024, China. Electronic address: majf247@nenu.edu.cn.
Anal Chim Acta ; 1276: 341653, 2023 Oct 02.
Article em En | MEDLINE | ID: mdl-37573094
ABSTRACT
A novel metal-organic framework [Co2LCl4]·2DMF (Co-L) based on thiacalix[4]arene derivative was synthesized using the solvothermal method. Then Co-L was respectively mixed with reduced graphene oxide (RGO), multi-walled carbon nanotubes (MWCNT) and mesoporous carbon (MC) to prepare corresponding composite materials. PXRD, SEM and N2 adsorption-desorption illustrated that composite materials have been successfully prepared. After optimizing experimental conditions for detecting chlorogenic acid (CGA), the Co-L@RGO(11) composite material showed the optimal electrocatalytic activity for CGA, which may be because RGO possessed large specific surface area and hydroxyl and carboxyl groups that could form hydrogen-bonding with the oxide of CGA. Benefiting from the synergetic effect of Co-L and RGO, the glassy carbon electrode modified with Co-L@RGO(11) (Co-L@RGO(11)/GCE) exhibited a low limit of detection (LOD) of 7.24 nM for CGA within the concentration of 0.1-2 µM and 2-20 µM. Co-L@RGO(11)/GCE also showed excellent selectivity, stability, and reproducibility for the CGA detection. Co-L@RGO(11)/GCE could detect the CGA in honeysuckle with satisfactory results. This work provided a great example for the thiacalix[4]arene-based MOF in the application of electrochemical sensors.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article