Your browser doesn't support javascript.
loading
Risk of Volar Locking Plate Removal After Distal Radius Fractures: Time-to-Event Analysis.
Holc, Fernando; Bronenberg Victorica, Pedro; Avanzi, Rocio; Huespe, Ivan A; De Carli, Pablo; Boretto, Jorge G.
Afiliação
  • Holc F; Hand and Upper Extremity Department, Instituto de Ortopedia y Traumatología "Prof. Dr. Carlos Ottolenghi", Hospital Italiano de Buenos Aires, Buenos Aires, Argentina. Electronic address: fernando.holc@hiba.org.ar.
  • Bronenberg Victorica P; Hand and Upper Extremity Department, Instituto de Ortopedia y Traumatología "Prof. Dr. Carlos Ottolenghi", Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.
  • Avanzi R; Hand and Upper Extremity Department, Instituto de Ortopedia y Traumatología "Prof. Dr. Carlos Ottolenghi", Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.
  • Huespe IA; Internal Medicine Research Area, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.
  • De Carli P; Hand and Upper Extremity Department, Instituto de Ortopedia y Traumatología "Prof. Dr. Carlos Ottolenghi", Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.
  • Boretto JG; Hand and Upper Extremity Department, Instituto de Ortopedia y Traumatología "Prof. Dr. Carlos Ottolenghi", Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.
J Hand Surg Am ; 48(10): 1011-1017, 2023 Oct.
Article em En | MEDLINE | ID: mdl-37578402
ABSTRACT

PURPOSE:

The primary purpose of this study was to describe the rate of volar locking plate (VLP) removal after distal radius fracture and how long it takes for the risk of VLP removal to stabilize. The secondary purpose was to describe the reasons for VLP removal and analyze the relationship between it and the Soong index.

METHODS:

This was a single-center retrospective cohort study. Patients aged >18 years with distal radius fracture who underwent VLP fixation were included. Hardware removal, time until VLP removal, and the primary reason for removal were recorded. The implant prominence was measured as described by Soong. We used Kaplan-Meier curves and risk tables to describe the risk of VLP removal and variation over time. Multivariable logistic regression was used to assess the relationship between Soong grade and VLP removal.

RESULTS:

A total of 313 wrists were included. There were 35 cases of VLP removal, with an overall incidence of 11.2% at 15 years of follow-up. The incidence rate was 1.2 per 100 individuals per year for the entire cohort. The risk of VLP removal decreased from 6.2% in the first postoperative year to 1.7% in the second year and 1.4% in the third year. Beyond that, the rate remained <1% per year throughout the follow-up period. The median hardware removal time was 11 months. The main reasons for VLP removal were tenosynovitis, implant-associated pain, and screw protrusion. We found no association between Soong grade and VLP removal.

CONCLUSIONS:

Volar locking plate removal after distal radius fracture was more common in the first year after surgery and remained notable until the third year. Regular monitoring and patient education to assess possible complications related to hardware are important during this period. TYPE OF STUDY/LEVEL OF EVIDENCE Therapeutic IV.