Your browser doesn't support javascript.
loading
Toward the rapid diagnosis of sepsis: dendritic copper nanostructure functionalized diazonium salt modified screen-printed graphene electrode for IL-6 detection.
Jesadabundit, Whitchuta; Jampasa, Sakda; Crapnell, Robert D; Dempsey, Nina C; Banks, Craig E; Siangproh, Weena; Chailapakul, Orawon.
Afiliação
  • Jesadabundit W; Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand.
  • Jampasa S; Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand.
  • Crapnell RD; Faculty of Science and Engineering, Manchester Metropolitan University, Manchester, M1 5GD, UK.
  • Dempsey NC; Faculty of Science and Engineering, Manchester Metropolitan University, Manchester, M1 5GD, UK.
  • Banks CE; Faculty of Science and Engineering, Manchester Metropolitan University, Manchester, M1 5GD, UK.
  • Siangproh W; Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand. weena@g.swu.ac.th.
  • Chailapakul O; Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand. corawon@chula.ac.th.
Mikrochim Acta ; 190(9): 362, 2023 08 23.
Article em En | MEDLINE | ID: mdl-37608141
ABSTRACT
Sepsis, an infectious disease affecting millions of people's health worldwide each year, calls for urgent attention to an improvement of analytical devices. Chemiluminescence immunoassay is a typical diagnostic method utilized to assess the risk development of sepsis. However, due to its high-cost, delayed, and complicated procedure, the practical utilization is therefore undoubtedly limited, especially for point-of-care test. Herein, we fabricated for the first time an immunosensor based on dendritic copper nanostructures (CuNSs) combined with 4-aminobenzoic acid (4-AB, the diazonium salt) as antibody linker modified on a screen-printed graphene electrode for the early detection of the sepsis biomarker interleukin-6 (IL-6). The electrode fabrication is made by electrodeposition, thus eliminating the multistep of nanomaterial synthesis and time wasting. The resulting dendritic CuNSs significantly increase the effective surface area (1.2 times) and the sensor's performance. The morphology of this combination was characterized using CV, EIS, SEM, EDX, and FTIR techniques. In the detection process, the appearance of IL-6 suppresses the current response of the redox probe indicator measured by differential pulse voltammetry due to the antibody-antigen complex. The subtraction of signal (ΔI) was interpreted as IL-6 concentration. This sensor exhibited a linear range from 0.05 to 500 pg mL-1 with low detection limit of 0.02 pg mL-1, proving a possibility for early sepsis screening. In addition, the established immunosensor can successfully quantify IL-6 in human serum sample, in which the results agreed well with those achieved using the standard approach, further showing high practical applicability of this developed immunosensor.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Sepse / Grafite Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Sepse / Grafite Idioma: En Ano de publicação: 2023 Tipo de documento: Article