Your browser doesn't support javascript.
loading
The pre-launch on-ground characterization of Ma_MISS spectrometer for ExoMars-Rosalind Franklin Rover mission. II. Radiometric calibration.
De Angelis, S; De Sanctis, M C; Altieri, F; Ferrari, M; Ammannito, E; Novi, S; Dami, M; Antonacci, F; Villa, F; Meini, M; Ruggiero, F; Fonte, S; Formisano, M; Frigeri, A; Tinivelli, P; Giardino, M; Mugnuolo, R; Pirrotta, S.
Afiliação
  • De Angelis S; INAF-IAPS, Via Fosso del Cavaliere, 100, 00133 Rome, Italy.
  • De Sanctis MC; INAF-IAPS, Via Fosso del Cavaliere, 100, 00133 Rome, Italy.
  • Altieri F; INAF-IAPS, Via Fosso del Cavaliere, 100, 00133 Rome, Italy.
  • Ferrari M; INAF-IAPS, Via Fosso del Cavaliere, 100, 00133 Rome, Italy.
  • Ammannito E; ASI-Italian Space Agency, Via del Politecnico snc, 00133 Rome, Italy.
  • Novi S; Sitael, Via Alessandro Gherardesca, 5, 56121 Pisa, Italy.
  • Dami M; Leonardo Company Finmeccanica, V. Delle Officine Galileo, 1, 50013 Campi Bisenzio FI, Italy.
  • Antonacci F; Leonardo Company Finmeccanica, V. Delle Officine Galileo, 1, 50013 Campi Bisenzio FI, Italy.
  • Villa F; Leonardo Company Finmeccanica, V. Delle Officine Galileo, 1, 50013 Campi Bisenzio FI, Italy.
  • Meini M; Sitael, Via Alessandro Gherardesca, 5, 56121 Pisa, Italy.
  • Ruggiero F; Leonardo Company Finmeccanica, V. Delle Officine Galileo, 1, 50013 Campi Bisenzio FI, Italy.
  • Fonte S; INAF-IAPS, Via Fosso del Cavaliere, 100, 00133 Rome, Italy.
  • Formisano M; INAF-IAPS, Via Fosso del Cavaliere, 100, 00133 Rome, Italy.
  • Frigeri A; INAF-IAPS, Via Fosso del Cavaliere, 100, 00133 Rome, Italy.
  • Tinivelli P; University of Perugia, Piazza Università, 1, 06123 Perugia, Italy.
  • Giardino M; ASI-Italian Space Agency, Via del Politecnico snc, 00133 Rome, Italy.
  • Mugnuolo R; ASI-Italian Space Agency, Centro di Geodesia Spaziale, 75100 Matera, Italy.
  • Pirrotta S; ASI-Italian Space Agency, Via del Politecnico snc, 00133 Rome, Italy.
Rev Sci Instrum ; 94(9)2023 Sep 01.
Article em En | MEDLINE | ID: mdl-37655988
The Ma_MISS miniaturized spectrometer is integrated within the Drilling System of the ExoMars Rosalind Franklin Rover for Mars exploration. Here we focus on the on ground calibration campaign to obtain radiometric and linearity calibrations of the Ma_MISS instrument, while the first paper dealt with the spectral calibration [De Angelis et al., Rev. Sci. Instrum. 93, 123704 (2022)]. The experimental setup used to carry out radiometric calibration is described, as are the methods used for data processing and key parameter retrieval. In particular, the Spectrometer Transfer Function (Responsivity), Signal-to-Noise Ratio, and detector linearity are determined. In a third paper [De Sanctis et al., Planet. Sci. J. 3, 142 (2022)], validation of the Ma_MISS calibration results through spectral measurements performed on rock and synthetic targets during the radiometric calibration campaign is described.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article