Your browser doesn't support javascript.
loading
Ablate and pace: Comparison of outcomes between conduction system pacing and biventricular pacing.
Palmisano, Pietro; Ziacchi, Matteo; Dell'Era, Gabriele; Donateo, Paolo; Ammendola, Ernesto; Aspromonte, Vittorio; Pellegrino, Pier Lugi; Del Giorno, Giuseppe; Coluccia, Giovanni; Bartoli, Lorenzo; Patti, Giuseppe; Senes, Jacopo; Parlavecchio, Antonio; Di Fraia, Francesco; Brunetti, Natale Daniele; Carbone, Angelo; Nigro, Gerardo; Biffi, Mauro; Accogli, Michele.
Afiliação
  • Palmisano P; Cardiology Unit, "Card. G. Panico" Hospital, Tricase, Italy.
  • Ziacchi M; Institute of Cardiology, University of Bologna, S. Orsola-Malpighi University Hospital, Bologna, Italy.
  • Dell'Era G; Division of Cardiology, University of Eastern Piedmont, Maggiore della Carità Hospital, Novara, Italy.
  • Donateo P; Department of Cardiology, Arrhythmology Center, Lavagna, Italy.
  • Ammendola E; Department of Cardiology, Monaldi Hospital, Second University of Naples, Naples, Italy.
  • Aspromonte V; Cardiology-Coronary Care Unit, Pugliese-Ciaccio Hospital, Catanzaro, Italy.
  • Pellegrino PL; Department of Cardiology, Policlinico Riuniti, University Hospital, Foggia, Italy.
  • Del Giorno G; Cardiology Unit, "Maria Ss Addolorata" Hospital, Eboli, Italy.
  • Coluccia G; Cardiology Unit, "Card. G. Panico" Hospital, Tricase, Italy.
  • Bartoli L; Institute of Cardiology, University of Bologna, S. Orsola-Malpighi University Hospital, Bologna, Italy.
  • Patti G; Division of Cardiology, University of Eastern Piedmont, Maggiore della Carità Hospital, Novara, Italy.
  • Senes J; Department of Cardiology, Arrhythmology Center, Lavagna, Italy.
  • Parlavecchio A; Cardiology Unit, Department of Clinical and Experimental Medicine, University of Messina, Messina, Italy.
  • Di Fraia F; Department of Cardiology, Monaldi Hospital, Second University of Naples, Naples, Italy.
  • Brunetti ND; Department of Cardiology, Policlinico Riuniti, University Hospital, Foggia, Italy.
  • Carbone A; Department of Medical and Surgical Sciences, University of Foggia, Foggia, Italy.
  • Nigro G; Cardiology Unit, "Maria Ss Addolorata" Hospital, Eboli, Italy.
  • Biffi M; Department of Cardiology, Monaldi Hospital, Second University of Naples, Naples, Italy.
  • Accogli M; Institute of Cardiology, University of Bologna, S. Orsola-Malpighi University Hospital, Bologna, Italy.
Pacing Clin Electrophysiol ; 46(10): 1258-1268, 2023 10.
Article em En | MEDLINE | ID: mdl-37665040
ABSTRACT

BACKGROUND:

Conduction system pacing (CSP), including His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP), have been proposed as alternatives to biventricular pacing (BVP) in patients scheduled for ablate and pace (A&P) strategy. The aim of this study was to compare the clinical outcomes, including the rate and nature of device-related complications, between BVP and CSP in a cohort of patients undergoing A&P.

METHODS:

Prospective, multicenter, observational study, enrolling consecutive patients undergoing A&P. The risk of device-related complications and of heart failure (HF) hospitalization was prospectively assessed.

RESULTS:

A total of 373 patients (75.3 ± 8.7 years, 53.9% male, 68.9% with NYHA class ≥III) were enrolled 263 with BVP, 68 with HBP, and 42 with LBBAP. Baseline characteristics of the three groups were similar. Compared to BVP and HBP, LBBAP was associated with the shortest mean procedural and fluoroscopy times and with the lowest acute capture thresholds (all p < .05). At 12-month follow-up LBBAP maintained the lowest capture thresholds and showed the longest estimated residual battery longevity (all p < .05). At 12-months follow-up the three study groups showed a similar risk of device-related complications (5.7%, 4.4%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .650), and of HF hospitalization (2.7%, 1.5%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .850).

CONCLUSIONS:

In the setting of A&P, CSP is a feasible pacing modality, with a midterm safety profile comparable to BVP. LBBAP offers the advantage of reducing procedural times and obtaining lower and stable capture thresholds, with a positive impact on the device longevity.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca Idioma: En Ano de publicação: 2023 Tipo de documento: Article