Your browser doesn't support javascript.
loading
Clinical presentations of acquired comitant esotropia in 5-35 years old Japanese and digital device usage: a multicenter registry data analysis study.
Iimori, Hirohito; Nishina, Sachiko; Hieda, Osamu; Goseki, Toshiaki; Nishikawa, Noriko; Suzuki, Sadao; Hikoya, Akiko; Komori, Miwa; Suzuki, Hiroko; Yoshida, Tomoyo; Hayashi, Shion; Mori, Takafumi; Kimura, Akiko; Morimoto, Takeshi; Shimizu, Yukiko; Negishi, Takashi; Shimizu, Tamami; Yokoyama, Yoshimi; Sugiyama, Yoshiko; Azuma, Noriyuki; Sato, Miho.
Afiliação
  • Iimori H; Department of Ophthalmology, Hamamatsu University School of Medicine, 1-20-1 Handa-yama, Higashi-ku, Hamamatsu, Japan.
  • Nishina S; Department of Ophthalmology, Ehime University, Toon, Japan.
  • Hieda O; Division of Ophthalmology, National Center for Child Health and Development, Tokyo, Japan.
  • Goseki T; Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan.
  • Nishikawa N; Department of Ophthalmology, Kitasato University, Sagamihara, Japan.
  • Suzuki S; Department of Ophthalmology, Kanagawa Dental University Yokohama Clinic, Yokohama, Japan.
  • Hikoya A; Department of Ophthalmology, International University of Health and Welfare, Atami Hospital, Atami, Japan.
  • Komori M; Department of Ophthalmology, Asahikawa Medical University, Asahikawa, Japan.
  • Suzuki H; Department of Public Health, Nagoya City University, Nagoya, Japan.
  • Yoshida T; Department of Ophthalmology, Hamamatsu University School of Medicine, 1-20-1 Handa-yama, Higashi-ku, Hamamatsu, Japan.
  • Hayashi S; Department of Ophthalmology, Hamamatsu University School of Medicine, 1-20-1 Handa-yama, Higashi-ku, Hamamatsu, Japan.
  • Mori T; Department of Ophthalmology, Hamamatsu University School of Medicine, 1-20-1 Handa-yama, Higashi-ku, Hamamatsu, Japan.
  • Kimura A; Division of Ophthalmology, National Center for Child Health and Development, Tokyo, Japan.
  • Morimoto T; Division of Ophthalmology, National Center for Child Health and Development, Tokyo, Japan.
  • Shimizu Y; Department of Ophthalmology, Yamagata University Faculty of Medicine, Yamagata, Japan.
  • Negishi T; Department of Ophthalmology, Fukushima Medical University, Fukushima, Japan.
  • Shimizu T; Department of Ophthalmology, Hyogo Medical University, Nishinomiya, Japan.
  • Yokoyama Y; Department of Ophthalmology, Osaka University Graduate School of Medicine, Suita, Japan.
  • Sugiyama Y; Department of Ophthalmology, Saneikai Tsukazaki Hospital, Himeji, Japan.
  • Azuma N; Department of Ophthalmology, Juntendo University Fuculty of Medicine, Tokyo, Japan.
  • Sato M; Department of Ophthalmology, Hamamatsu University School of Medicine, 1-20-1 Handa-yama, Higashi-ku, Hamamatsu, Japan.
Jpn J Ophthalmol ; 67(6): 629-636, 2023 Nov.
Article em En | MEDLINE | ID: mdl-37695434
ABSTRACT

PURPOSE:

To describe clinical presentations of acquired comitant esotropia and digital device use in children, adolescents, and young adults without neurological problems. STUDY

DESIGN:

Multicenter prospective observational study.

METHODS:

Patients with acquired comitant esotropia, without intracranial diseases aged 5-35 years at the time of visit, who were seen at pre-registered facilities within 1 year of onset were enrolled. The duration from the onset of symptoms and the time of digital device usage approximately 1 month before onset and their lifestyles were surveyed. Visual acuity, cycloplegic refraction, and strabismus angles were measured. Data were analyzed in three age groups (Child 5-12 years, Adolescent 13-18 years, and Young adult 19-35 years).

RESULTS:

Between November 2019 and December 2021, 218 patients were enrolled from 55 facilities, and 194 patients (including 62 children, 69 adolescents, and 63 young adults) were analyzed. The child group spent the least amount of time using digital devices (children 159; adolescents 210; young adults 267 min/work day, p < 0.05; (mean time in the same order below) 229, 338, 314 min/holiday, p < 0.05) and had the largest strabismus angle (mean strabismus angle at near 30, 22, 18 PD, p < 0.01; at far 28, 26, 21 PD, p<0.05).

CONCLUSION:

The clinical features of acquired comitant esotropia and hand-held digital device usage differed between children aged ≤ 12 years and older patients. This report gives the current clinical characteristics of young patients with acquired esotropia and digital device usage.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Esotropia / Estrabismo Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Esotropia / Estrabismo Idioma: En Ano de publicação: 2023 Tipo de documento: Article