Your browser doesn't support javascript.
loading
Differences between CEUS LI-RADS and CECT LI-RADS in the diagnosis of focal liver lesions in patients at risk for HCC.
Wen, Rong; Huang, Weiche; Song, Rui; Qin, Lanhui; Wu, Yuquan; Peng, Yuting; Huang, Xiongyan; He, Yun; Yang, Hong.
Afiliação
  • Wen R; Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, China.
  • Huang W; Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, China.
  • Song R; Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, China.
  • Qin L; Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, China.
  • Wu Y; Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, China.
  • Peng Y; Department of Medical Ultrasound, The Second Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, China.
  • Huang X; Department of Pathology, The Affiliated Minzu Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, China.
  • He Y; Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, China.
  • Yang H; Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, China. yanghong@gxmu.edu.cn.
BMC Med Imaging ; 23(1): 122, 2023 09 11.
Article em En | MEDLINE | ID: mdl-37697248
OBJECTIVES: To compare the inter-modality consistency and diagnostic performances of the contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) and contrast-enhanced computed tomography (CECT) LI-RADS in patients at risk for hepatocellular carcinoma (HCC), so as to help clinicians to select a more appropriate modality to follow the focal liver lesions (FLLs). METHODS: This retrospective study included untreated 277 FLLs from 247 patients who underwent both CEUS and CECT within 1 month. The ultrasound contrast medium used was SonoVue. FLL categories were independently assigned by two ultrasound physicians and two radiologists using CEUS LI-RADS v2017 and CECT LI-RADS v2018, respectively. The diagnostic performances of CEUS and CECT LI-RADS were evaluated using sensitivity, specificity, positive predictive value (PPV), and negative predictive value. Cohen's Kappa was employed to evaluate the concordance of the LI-RADS category. RESULTS: The inter-modality consistency for CEUS and CECT LI-RADS was 0.31 (p < 0.001). HCC was more frequently observed in CECT LR-3 and LR-4 hepatic lesions than in CEUS (7.3% vs. 19.5%, p < 0.001). The specificity and PPV of CEUS and CECT LR-5 for the diagnosis of HCC were 89.5%, 95.0%, and 82.5%, 94.4%, respectively. The sensitivity of CEUS LR-5 + LR-M for the diagnosis of hepatic malignancies was higher than that of CECT (93.7% vs. 82.7%, p < 0.001). The specificity and PPV of CEUS LR-M for the diagnosis of non-HCC malignancies were lower than those of CECT (59.7% vs. 95.5%, p < 0.001; 23.4% vs. 70.3%, p < 0.001). CONCLUSIONS: The inter-modality consistency between the CEUS and CECT LI-RADS categories is fair. CEUS LI-RADS was more sensitive than CECT LI-RADS in terms of identifying hepatic malignancies, but weaker in terms of separating HCC from non-HCC malignancies.