Your browser doesn't support javascript.
loading
Feasibility evaluation of N-Isopropyl Acrylamide 3D gel dosimeters for proton therapy.
Yao, Chun-Hsu; Huang, Eng-Yen; Juan, Kuo-Jung; Juang, Pei-Jiuan; Juan, Ying-Hsuan; Chang, Yuan-Jen.
Afiliação
  • Yao CH; Department of Master Program for Biomedical Engineering / School of Chinese Medicine, China Medical University, Taichung City, Taiwan, R.O.C.
  • Huang EY; Biomaterials Translational Research Center, China Medical University Hospital, Taichung City, Taiwan, R.O.C.
  • Juan KJ; Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung City, Taiwan, R.O.C.
  • Juang PJ; School of Chinese Medicine, China Medical University, Taichung City, Taiwan, R.O.C.
  • Juan YH; Department of Biomedical Informatics, Asia University, Taichung City, Taiwan, R.O.C.
  • Chang YJ; Department of Radiation Oncology, Chang Gung Memorial Hospital Kaohsiung Branch, Niao-Sung District, Kaohsiung, Taiwan, R.O.C.
PLoS One ; 18(9): e0291507, 2023.
Article em En | MEDLINE | ID: mdl-37699042
ABSTRACT
This study aimed to investigate the feasibility of applying 3D gel dosimeters for proton therapy. Two different formulations (5-5-3-5, 5-3-3-10) for the N-Isopropyl Acrylamide (NIPAM) polymer gel were used to find the best composition for the application of NIPAM polymer gels for proton therapy. The reaction of the gel under different physical conditions, including dependence on energy and dependence on the dose rate of the NIPAM gel under proton irradiation, was also explored. A NIPAM gel dosimeter was used to record the 3D dose distribution, and a self-developed parallel beam optical computed tomography scanner was used to obtain non-irradiated and post-irradiated gel phantom images. The NIPAM gel was filled into a cylindrical acrylic phantom. The results showed that the optical density of the irradiated NIPAM dosimeter was linear in the dose range of 0 to 6 Gy, and the linearity of the two NIPAM gel formulations at the depth of the dose point (2 cm) was 0.98 to 0.89. The dose depth curves showed different patterns with different gel sensitivities. This study demonstrated that the NIPAM gel dosimeter with the 5-3-3-10 formulation is suitable for verifying the dosimetry dose of proton beams.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia com Prótons Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia com Prótons Idioma: En Ano de publicação: 2023 Tipo de documento: Article