Your browser doesn't support javascript.
loading
Evaluation of the QIAstat-Dx Meningitis/Encephalitis Panel, a multiplex PCR platform for the detection of community-acquired meningoencephalitis.
Sundelin, Thomas; Bialas, Johanna; de Diego, Juana; Hermanowski, Markus; Leibhan, Hendrik; Ponderand, Léa; Juanola-Falgarona, Marti; Jones, Tara; Rey, Melisa; Johnson, Sarah; Pareja, Josep; Caspar, Yvan.
Afiliação
  • Sundelin T; Department of Clinical Microbiology, Herlev and Gentofte Hospital , Herlev, Denmark.
  • Bialas J; Labor Berlin-Charite Vivantes Services GmbH , Berlin, Germany.
  • de Diego J; Labor Berlin-Charite Vivantes Services GmbH , Berlin, Germany.
  • Hermanowski M; Labor Berlin-Charite Vivantes Services GmbH , Berlin, Germany.
  • Leibhan H; Labor Berlin-Charite Vivantes Services GmbH , Berlin, Germany.
  • Ponderand L; Laboratoire de bactériologie, CHU Grenoble Alpes , La Tronche, France.
  • Juanola-Falgarona M; Université Grenoble Alpes, CEA, CNRS, IBS , Grenoble, France.
  • Jones T; STAT-Dx Life S.L. (a QIAGEN Company), Carrer de Baldiri Reixac , Barcelona, Spain.
  • Rey M; QIAGEN Ltd , Manchester, United Kingdom.
  • Johnson S; STAT-Dx Life S.L. (a QIAGEN Company), Carrer de Baldiri Reixac , Barcelona, Spain.
  • Pareja J; QIAGEN Ltd , Manchester, United Kingdom.
  • Caspar Y; STAT-Dx Life S.L. (a QIAGEN Company), Carrer de Baldiri Reixac , Barcelona, Spain.
J Clin Microbiol ; 61(10): e0042623, 2023 10 24.
Article em En | MEDLINE | ID: mdl-37702495
ABSTRACT
Rapid identification of the causative pathogens of central nervous system infections is essential for providing appropriate management and improving patient outcomes. The performance of QIAstat-Dx Meningitis/Encephalitis (ME) Panel-a multiplex PCR testing platform-in detecting pathogens implicated in meningitis and/or encephalitis was evaluated using BioFire FilmArray ME Panel as a comparator method. This multicenter study analyzed 585 retrospective residual cerebrospinal fluid specimens and 367 contrived specimens. The QIAstat-Dx ME Panel showed positive percent agreement (PPA) values of 100% for Neisseria meningitidis, Streptococcus agalactiae, Escherichia coli K1, Listeria monocytogenes, and Cryptococcus gattii/neoformans on clinical samples compared to the BioFire FilmArray ME Panel. The PPA values observed for Haemophilus influenzae and Streptococcus pneumoniae were 80% and 88.24%, respectively. Negative percent agreement (NPA) values were >99.0% for each of the six bacterial targets and one fungal target tested with clinical samples. One viral target, herpes simplex virus 1, exhibited a PPA value of 100.0%, while the remaining viral targets-human parechovirus, herpes simplex virus 2, human herpes virus 6, and varicella zoster virus-were >90.0%, with the exception of enterovirus, which had a PPA value of 77.8%. The QIAstat-Dx ME Panel detected five true-positive and four true-negative cases compared to BioFire FilmArray ME Panel. The NPA values for all viral pathogens were >99.0%. Overall, the QIAstat-Dx ME Panel showed comparable performance to the BioFire FilmArray ME Panel as a rapid diagnostic tool for community-acquired meningitis and encephalitis.