Comparison of the STANDARD F and SD BIOLINE stool antigen tests for diagnosis of Helicobacter pylori infection.
Diagn Microbiol Infect Dis
; 107(4): 116051, 2023 Dec.
Article
em En
| MEDLINE
| ID: mdl-37708643
We compared the performance of the STANDARD F and SD BIOLINE stool antigen tests in 335 patients. The performance of STANDARD F (sensitivity: 95.6%; specificity: 94%) was highly comparable to that of SD BIOLINE (sensitivity: 92.6%; specificity: 93.5%), suggesting that STANDARD F is useful for the detection of Helicobacter pylori infection.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Helicobacter pylori
/
Infecções por Helicobacter
Idioma:
En
Ano de publicação:
2023
Tipo de documento:
Article