Your browser doesn't support javascript.
loading
Photoswitching alters fluorescence readout of jGCaMP8 Ca2+ indicators tethered to Orai1 channels.
Dynes, Joseph L; Yeromin, Andriy V; Cahalan, Michael D.
Afiliação
  • Dynes JL; Department of Physiology and Biophysics, University of California, Irvine, CA 92697.
  • Yeromin AV; Department of Physiology and Biophysics, University of California, Irvine, CA 92697.
  • Cahalan MD; Department of Physiology and Biophysics, University of California, Irvine, CA 92697.
Proc Natl Acad Sci U S A ; 120(39): e2309328120, 2023 09 26.
Article em En | MEDLINE | ID: mdl-37729200
We used electrophysiology and Ca2+ channel tethering to evaluate the performance of jGCaMP8 genetically encoded Ca2+ indicators (GECIs). Orai1 Ca2+ channel-jGCaMP8 fusions were transfected into HEK 293A cells and jGCaMP8 fluorescence responses recorded by simultaneous total internal reflection fluorescence microscopy and whole-cell patch clamp electrophysiology. Noninactivating currents from the Orai1 Y80E mutant provided a steady flux of Ca2+ controlled on a millisecond time scale by step changes in membrane potential. Test pulses to -100 mV produced Orai1 Y80E-jGCaMP8f fluorescence traces that unexpectedly declined by ~50% over 100 ms before reaching a stable plateau. Testing of Orai1-jGCaMP8f using unroofed cells further demonstrated that rapid and partial fluorescence inactivation is a property of the indicator itself, rather than channel function. Photoinactivation spontaneously recovered over 5 min in the dark, and recovery was accelerated in the absence of Ca2+. Mutational analysis of residues near the tripeptide fluorophore of jGCaMP8f pointed to a mechanism: Q69M/C70V greatly increased (~90%) photoinactivation, reminiscent of fluorescent protein fluorophore cis-trans photoswitching. Indeed, 405-nm illumination of jGCaMP8f or 8m/8s/6f led to immediate photorecovery, and simultaneous illumination with 405 and 488-nm light blocked photoinactivation. Subsequent mutagenesis produced a variant, V203Y, that lacks photoinactivation but largely preserves the desirable properties of jGCaMP8f. Our results point to caution in interpreting rapidly changing Ca2+ signals using jGCaMP8 and earlier series GECIs, suggest strategies to avoid photoswitching, and serve as a starting point to produce more photostable, and thus more accurate, GECI derivatives.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Iluminação / Corantes Fluorescentes Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Iluminação / Corantes Fluorescentes Idioma: En Ano de publicação: 2023 Tipo de documento: Article