Mechanosensitive ion channel gene survey suggests potential roles in primary open angle glaucoma.
Liu, Wendy W; Kinzy, Tyler G; Cooke Bailey, Jessica N; Xu, Zihe; Hysi, Pirro; Wiggs, Janey L.
Afiliação
  • Liu WW; Spencer Center for Vision Research, Byers Eye Institute, Stanford University School of Medicine, 2370 Watson Court, Palo Alto, CA, 94303, USA. wendywliu@stanford.edu.
  • Kinzy TG; Department of Population and Quantitative Health Sciences, Cleveland Institute for Computational Biology, Case Western Reserve University, Cleveland, OH, USA.
  • Cooke Bailey JN; Department of Population and Quantitative Health Sciences, Cleveland Institute for Computational Biology, Case Western Reserve University, Cleveland, OH, USA.
  • Xu Z; Department of Ophthalmology, King's College London, St. Thomas' Hospital, London, UK.
  • Hysi P; Department of Ophthalmology, King's College London, St. Thomas' Hospital, London, UK.
  • Wiggs JL; Department of Twin Research and Genetic Epidemiology, King's College London, St. Thomas' Hospital, London, UK.
Sci Rep ; 13(1): 15871, 2023 09 23.
Article em En | MEDLINE | ID: mdl-37741866
ABSTRACT
Although glaucoma is a disease modulated by eye pressure, the mechanisms of pressure sensing in the eye are not well understood. Here, we investigated associations between mechanosensitive ion channel gene variants and primary open-angle glaucoma (POAG). Common (minor allele frequency > 5%) single nucleotide polymorphisms located within the genomic regions of 20 mechanosensitive ion channel genes in the K2P, TMEM63, PIEZO and TRP channel families were assessed using genotype data from the NEIGHBORHOOD consortium of 3853 cases and 33,480 controls. Rare (minor allele frequency < 1%) coding variants were assessed using exome array genotyping data for 2606 cases and 2606 controls. Association with POAG was analyzed using logistic regression adjusting for age and sex. Two rare PIEZO1 coding variants with protective effects were identified in the NEIGHBOR dataset R1527H, (OR 0.17, P = 0.0018) and a variant that alters a canonical splice donor site, g.16-88737727-C-G Hg38 (OR 0.38, P = 0.02). Both variants showed similar effects in the UK Biobank and the R1527H also in the FinnGen database. Several common variants also reached study-specific thresholds for association in the NEIGHBORHOOD dataset. These results identify novel variants in several mechanosensitive channel genes that show associations with POAG, suggesting that these channels may be potential therapeutic targets.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Glaucoma de Ângulo Aberto Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Glaucoma de Ângulo Aberto Idioma: En Ano de publicação: 2023 Tipo de documento: Article