Your browser doesn't support javascript.
loading
Multicomponent Analysis of Liuwei Dihuang Pills by a Single Marker Quantification Method and Chemometric Discrimination of Fingerprints.
Yang, Lin; Li, Yan; Hou, Yuanfang; Wu, Yongfu; Tan, Lihong; Mu, Zhenqiang; Zhu, Zhaojing; He, Dan.
Afiliação
  • Yang L; Chongqing Pharmaceutical Preparation Engineering Technology Research Center, Chongqing Medical and Pharmaceutical College, Chongqing 401331, China.
  • Li Y; Chongqing Pharmaceutical Preparation Engineering Technology Research Center, Chongqing Medical and Pharmaceutical College, Chongqing 401331, China.
  • Hou Y; Chongqing Pharmaceutical Preparation Engineering Technology Research Center, Chongqing Medical and Pharmaceutical College, Chongqing 401331, China.
  • Wu Y; Traditional Chinese Medicine Factory Co. Ltd., Taiji Group Chongqing, Chongqing 402284, China.
  • Tan L; Chongqing Pharmaceutical Preparation Engineering Technology Research Center, Chongqing Medical and Pharmaceutical College, Chongqing 401331, China.
  • Mu Z; Chongqing Pharmaceutical Preparation Engineering Technology Research Center, Chongqing Medical and Pharmaceutical College, Chongqing 401331, China.
  • Zhu Z; Chongqing Pharmaceutical Preparation Engineering Technology Research Center, Chongqing Medical and Pharmaceutical College, Chongqing 401331, China.
  • He D; Chongqing Research Center for Pharmaceutical Engineering, College of Pharmacy, Chongqing Medical University, Chongqing 400016, China.
J Anal Methods Chem ; 2023: 6648668, 2023.
Article em En | MEDLINE | ID: mdl-37743973
ABSTRACT
An effective and comprehensive quality evaluation method for Liuwei Dihuang pills (LDP) was established by the simultaneous determination of 8 active components in LDP by the quantitative analysis of multicomponents by single marker (QAMS) method and high-performance liquid chromatography (HPLC) fingerprint combined with chemometrics. These 8 active components were determined by QAMS and the external standard method (ESM), and the quantitative results of the two methods were compared to validate the accuracy and feasibility of the QAMS method. 8 active components showed good linear relationships within their ranges, whose average recoveries were 99.7∼102.3%. No significant difference was found (P > 0.05) in the quantitative results determined by QAMS and ESM. Furthermore, the fingerprint of LDP was also established, with 11 common peaks identified, and the similarity of the fingerprints of 21 batches of LDP was greater than 0.95. The 21 batches of LDP were basically divided into 3 groups by hierarchical cluster analysis (HCA) and principal component analysis (PCA), and 3 differential markers were screened out by orthogonal partial least squares discriminant analysis (OPLS-DA). The established QAMS method is accurate, economical, fast, and convenient and can simultaneously determine the content of 8 active components in LDP. HPLC fingerprint combined with chemometric analysis more comprehensively evaluated the quality consistency of different batches of LDP and analyzed the markers that cause quality differences between batches. It can provide a scientific basis and reference of quality consistency evaluation for the manufacturers and drug regulatory departments of the preparation.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article