Your browser doesn't support javascript.
loading
[The efficacy of thin struct bare stents for the treatment of spontaneous isolated dissection of the superior mesenteric artery].
Ni, J Q; Fan, X X; He, C S; Xu, L; Shen, L; Jin, Q; Wang, G L; Jing, Z P; Sun, Y D.
Afiliação
  • Ni JQ; Department of Vascular Surgery, First Hospital of Jiaxing, Jiaxing 314001, China.
  • Fan XX; Department of General Surgery, Jinling Hospital, Nanjing University, Nanjing 210002, China.
  • He CS; Department of General Surgery, Jinling Hospital, Nanjing University, Nanjing 210002, China.
  • Xu L; Department of Vascular Surgery, First Hospital of Jiaxing, Jiaxing 314001, China.
  • Shen L; Department of Vascular Surgery, First Hospital of Jiaxing, Jiaxing 314001, China.
  • Jin Q; Department of Vascular Surgery, First Hospital of Jiaxing, Jiaxing 314001, China.
  • Wang GL; Department of Vascular Surgery, First Hospital of Jiaxing, Jiaxing 314001, China.
  • Jing ZP; Department of Vascular Surgery, Chhanghai Hospital, Naval Military Medical University, Shanghai 200433, China.
  • Sun YD; Department of General Surgery, Jinling Hospital, Nanjing University, Nanjing 210002, China.
Zhonghua Wai Ke Za Zhi ; 61(11): 1002-1006, 2023 Sep 27.
Article em Zh | MEDLINE | ID: mdl-37767667
ABSTRACT

Objective:

To examine the safety and effectiveness of thin struct bare stents for the treatment of spontaneous isolated dissection of the superior mesenteric artery (SIDSMA).

Methods:

The data of 32 patients admitted to First Hospital of Jiaxing (20 cases) and Jinling Hospital (12 cases) with SIDSMA from January 2016 to January 2021 were retrospectively analyzed. There were 27 males and 5 females, aging (54.8±9.4) years (range 36 to 75 years). All patients were treated with thin struct bare stents. Controllable spring coils were used to fulfill the false lumen in 2 cases. Symptoms, vascular remodeling pattern at the SIDSMA lesion, and patency of the stents were observed during follow-up.

Results:

The surgical success rate was 100%. According to the length of the lesions and stents, the number of stents implanted was 1 in 17 cases, 2 in 11 cases and 3 in 4 cases. The angiography showed that blood flow in the stent was smooth and that the false lumen disappeared or weakened. The numerical rating scale for abdominal pain decreased from 6.1±1.5 (range 4 to 10) preoperatively to 1.0 (1.0) (range 0 to 3) 1 hour postoperatively (W=528, P<0.01). The compression rate of the true lumen of the superior mesenteric artery decreased from (92.3±6.7)% (range 25% to 94%) preoperatively to 0.8 (1.2)% (range 0 to 3.2%) 1 month postoperatively (W=528, P<0.01). The primary patency rate of CT angiography at 1 month postoperatively was 100%. The vascular remodeling rate was (92.3±6.7)% (range 80% to 100%). All patients were followed for (46.3±17.0) months (range 24 to 76 months). The cumulative patency rates in 1, 2 and 5 years were all 100%.

Conclusion:

The use of thin struct bare stents for SIDSMA is safety and efficacy.