Your browser doesn't support javascript.
loading
Nanozymes based on octahedral platinum nanocrystals with {111} surface facets: glucose oxidase mimicking activity in electrochemical sensors.
Mazzotta, Elisabetta; Di Giulio, Tiziano; Mastronardi, Valentina; Brescia, Rosaria; Pompa, Pier Paolo; Moglianetti, Mauro; Malitesta, Cosimino.
Afiliação
  • Mazzotta E; Laboratorio di Chimica Analitica, Dipartimento di Scienze e Tecnologie Biologiche e Ambientali (Di.S.Te.B.A.), Università del Salento, 73100, Lecce, Italy. elisabetta.mazzotta@unisalento.it.
  • Di Giulio T; Laboratorio di Chimica Analitica, Dipartimento di Scienze e Tecnologie Biologiche e Ambientali (Di.S.Te.B.A.), Università del Salento, 73100, Lecce, Italy.
  • Mastronardi V; Istituto Italiano di Tecnologia, Nanobiointeractions & Nanodiagnostics, Via Morego 30, 16163, Genova, Italy.
  • Brescia R; Electron Microscopy Facility, Istituto Italiano di Tecnologia, Via Morego 30, 16163, Genova, Italy.
  • Pompa PP; Istituto Italiano di Tecnologia, Nanobiointeractions & Nanodiagnostics, Via Morego 30, 16163, Genova, Italy.
  • Moglianetti M; Istituto Italiano di Tecnologia, Nanobiointeractions & Nanodiagnostics, Via Morego 30, 16163, Genova, Italy. mauro.moglianetti@iit.it.
  • Malitesta C; Istituto Italiano di Tecnologia, Centre for Cultural Heritage Technology (CCHT@Ca' Foscari), Via Torino 155, 30172, Venice, Italy. mauro.moglianetti@iit.it.
Mikrochim Acta ; 190(10): 425, 2023 09 30.
Article em En | MEDLINE | ID: mdl-37776360
The ability of shape-controlled octahedral Pt nanoparticles to act as nanozyme mimicking glucose oxidase enzyme is reported. Extended {111} particle surface facets coupled with a size comparable to natural enzymes and easy-to-remove citrate coating give high affinity for glucose, comparable to the enzyme as proven by the steady-state kinetics of glucose electrooxidation. The easy and thorough removal of the citrate coating, demonstrated by X-ray photoelectron spectroscopy analysis, allows a highly stable deposition of the nanozymes on the electrode. The glucose electrochemical detection (at -0.2 V vs SCE) shows a linear response between 0.36 and 17 mM with a limit of detection of 110 µM. A good reproducibility has been achieved, with an average relative standard deviation (RSD) value of 9.1% (n = 3). Similarly, a low intra-sensor variability has been observed, with a RSD of 6.6% (n = 3). Moreover, the sensor shows a long-term stability with reproducible performances for at least 2 months (RSD: 7.8%). Tests in saliva samples show the applicability of Pt nanozymes to commercial systems for non-invasive monitoring of hyperglycemia in saliva, with recoveries ranging from 92 to 98%.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nanopartículas / Glucose Oxidase Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nanopartículas / Glucose Oxidase Idioma: En Ano de publicação: 2023 Tipo de documento: Article