Your browser doesn't support javascript.
loading
Gold nanoparticle dimer-based immunochromatography for in situ ultrasensitive detection of porcine epidemic diarrhea virus.
Shi, Xinrui; Luo, Yaxiang; Yan, Hao; Tian, Guangzhao; Yang, Songxin; He, Zhaoyuan; Zhang, Fuxin; Wang, Yueliang; Guo, Longhua; Chen, Hailan.
Afiliação
  • Shi X; College of Animal Science and Technology, Guangxi University, Nanning, 530005, Guangxi, China.
  • Luo Y; Guangxi Zhuang Autonomous Region Engineering Research Center of Veterinary Biologics, Nanning, 530004, Guangxi, China.
  • Yan H; College of Animal Science and Technology, Guangxi University, Nanning, 530005, Guangxi, China.
  • Tian G; Guangxi Zhuang Autonomous Region Engineering Research Center of Veterinary Biologics, Nanning, 530004, Guangxi, China.
  • Yang S; College of Animal Science and Technology, Guangxi University, Nanning, 530005, Guangxi, China.
  • He Z; Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing, Zhejiang, 314001, China.
  • Zhang F; College of Animal Science and Technology, Guangxi University, Nanning, 530005, Guangxi, China.
  • Wang Y; Guangxi Zhuang Autonomous Region Engineering Research Center of Veterinary Biologics, Nanning, 530004, Guangxi, China.
  • Guo L; College of Animal Science and Technology, Guangxi University, Nanning, 530005, Guangxi, China.
  • Chen H; Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing, Zhejiang, 314001, China.
Mikrochim Acta ; 190(11): 430, 2023 10 07.
Article em En | MEDLINE | ID: mdl-37804452
ABSTRACT
The low detection sensitivity of lateral-flow immunochromatography assay (LFIA) based on spherical gold nanoparticle (AuNP) limits its wide applications. In the present study, AuNP dimers with strong plasma scattering and robust signal output were synthesized via the Ag ion soldering (AIS) strategy and used as labeled probes in LFIA to boost the sensitivity without any extra operation process and equipment. The established LFIA exhibited high sensitivity with a limit of detection (LOD) of 2.0 × 102 TCID50/mL for PEDV, which provides 50 times higher sensitivity than commercial LFIA based on spherical colloidal gold. In addition, the AuNP dimer-based LFIA showed strong specificity, good reproducibility, high stability, and good accordance to reverse transcription polymer chain reaction (RT-PCR) when detecting 109 clinical samples. Thus, the AuNP dimers is a promising probe for LFIA and the developed AuNP dimer-based LFIA is suitable for the rapid detection of PEDV in the field.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças dos Suínos / Vírus da Diarreia Epidêmica Suína / Nanopartículas Metálicas Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças dos Suínos / Vírus da Diarreia Epidêmica Suína / Nanopartículas Metálicas Idioma: En Ano de publicação: 2023 Tipo de documento: Article