Your browser doesn't support javascript.
loading
EURADOS project on the impact of the proposed ICRU operational dose quantities.
Gilvin, Phil; Caresana, Marco; Bottollier-Depois, Jean-Francois; Chumak, Vadim; Clairand, Isabelle; Eakins, Jonathan; Ferrari, Paolo; Hupe, Oliver; Olko, Pawel; Röttger, A; Tanner, Rick; Vanhavere, Filip; Bakhanova, Elena; Bandalo, Vedran; Ekendahl, Daniela; Hödlmoser, Herbert; Matthiä, Daniel; Reitz, Günther; Latocha, Marcin; Beck, Peter; Thomas, David; Behrens, Rolf.
Afiliação
  • Gilvin P; UK Health Security Agency, Chilton, Didcot, OXON OX11 0RQ, UK.
  • Caresana M; Politecnico di Milano, Department of Energy, Via la Masa 34, Milano 20156, Italy.
  • Bottollier-Depois JF; Institute for Radiological Protection and Nuclear Safety, PSE-SANTE BP 17, Fontenay-aux-Roses 92262, France.
  • Chumak V; Dosimetrica LLC, Division of Prospective Dosimetric Studies, PO Box 40, Kyiv 4119, Ukraine.
  • Clairand I; Institute for Radiological Protection and Nuclear Safety, PSE-SANTE BP 17, Fontenay-aux-Roses 92262, France.
  • Eakins J; UK Health Security Agency, Chilton, Didcot, OXON OX11 0RQ, UK.
  • Ferrari P; ENEA IRP - Radiation Protection Institute, 4 Via Martiri di Monte Sole, Bologna 40129, Italy.
  • Hupe O; Physikalisch-Technische Bundesanstalt, Bundesallee 100, Braunschweig 38116, Germany.
  • Olko P; Institute of Nuclear Physics PAN, Division of Applied Physics, Radzikowskiego 152, Kraków 31-342, Poland.
  • Röttger A; Physikalisch-Technische Bundesanstalt, Bundesallee 100, Braunschweig 38116, Germany.
  • Tanner R; UK Health Security Agency, Chilton, Didcot, OXON OX11 0RQ, UK.
  • Vanhavere F; Belgian Nuclear Research Centre, Environment, Health and Safety, Boeretang 200, Mol 2400, Belgium.
  • Bakhanova E; Dosimetrica LLC, Division of Prospective Dosimetric Studies, PO Box 40, Kyiv 4119, Ukraine.
  • Bandalo V; Mirion Technologies (AWST) GmbH, Otto-Hahn-Ring 6, Munich 81739, Germany.
  • Ekendahl D; National Radiation Protection Institute, Bartoskova 28, Prague 14000, Czech Republic.
  • Hödlmoser H; Mirion Technologies (AWST) GmbH, Otto-Hahn-Ring 6, Munich 81739, Germany.
  • Matthiä D; German Aerospace Centre, Köln 51147, Germany.
  • Reitz G; German Aerospace Centre, Köln 51147, Germany.
  • Latocha M; Seibersdorf Labor GmbH, Seibersdorf 2444, Austria.
  • Beck P; Seibersdorf Labor GmbH, Seibersdorf 2444, Austria.
  • Thomas D; National Physical Laboratory, Teddington, Middlesex TW11 0LW, UK.
  • Behrens R; Physikalisch-Technische Bundesanstalt, Bundesallee 100, Braunschweig 38116, Germany.
Radiat Prot Dosimetry ; 199(15-16): 1689-1695, 2023 Oct 11.
Article em En | MEDLINE | ID: mdl-37819353
ABSTRACT
Following the publication of the joint The International Commissions on Radiation Units and Measurements (ICRU) and on Radiological Protection (ICRP) report on new operational quantities for radiation protection, the European Dosimetry Group (EURADOS) have carried out an initial evaluation. The EURADOS report analyses the impact that the new quantities will have on radiation protection practice; calibration and reference fields; European and national regulation; international standards and, especially, dosemeter and instrument design. The task group included experienced scientists drawn from across the various EURADOS working groups.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Monitoramento de Radiação Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Monitoramento de Radiação Idioma: En Ano de publicação: 2023 Tipo de documento: Article