Your browser doesn't support javascript.
loading
A Monte Carlo dose recalculation pipeline for durable datasets: an I-125 LDR prostate brachytherapy use case.
Ouellet, Samuel; Lemaréchal, Yannick; Berumen-Murillo, Francisco; Lavallée, Marie-Claude; Vigneault, Éric; Martin, André-Guy; Foster, William; Thomson, Rowan M; Després, Philippe; Beaulieu, Luc.
Afiliação
  • Ouellet S; Département de physique, de génie physique et d'optique, et Centre de recherche sur le cancer, Université Laval, Québec, Québec, Canada.
  • Lemaréchal Y; Service de radio-oncologie et Axe Oncologie du CRCHU de Québec, CHU de Québec-Université Laval, Quebec, QC, Canada.
  • Berumen-Murillo F; Département de physique, de génie physique et d'optique, et Centre de recherche sur le cancer, Université Laval, Québec, Québec, Canada.
  • Lavallée MC; Service de radio-oncologie et Axe Oncologie du CRCHU de Québec, CHU de Québec-Université Laval, Quebec, QC, Canada.
  • Vigneault É; Département de physique, de génie physique et d'optique, et Centre de recherche sur le cancer, Université Laval, Québec, Québec, Canada.
  • Martin AG; Service de radio-oncologie et Axe Oncologie du CRCHU de Québec, CHU de Québec-Université Laval, Quebec, QC, Canada.
  • Foster W; Département de physique, de génie physique et d'optique, et Centre de recherche sur le cancer, Université Laval, Québec, Québec, Canada.
  • Thomson RM; Service de radio-oncologie et Axe Oncologie du CRCHU de Québec, CHU de Québec-Université Laval, Quebec, QC, Canada.
  • Després P; Service de radio-oncologie et Axe Oncologie du CRCHU de Québec, CHU de Québec-Université Laval, Quebec, QC, Canada.
  • Beaulieu L; Service de radio-oncologie et Axe Oncologie du CRCHU de Québec, CHU de Québec-Université Laval, Quebec, QC, Canada.
Phys Med Biol ; 68(23)2023 Nov 20.
Article em En | MEDLINE | ID: mdl-37863069
ABSTRACT
Monte Carlo (MC) dose datasets are valuable for large-scale dosimetric studies. This work aims to build and validate a DICOM-compliant automated MC dose recalculation pipeline with an application to the production of I-125 low dose-rate prostate brachytherapy MC datasets. Built as a self-contained application, the recalculation pipeline ingested clinical DICOM-RT studies, reproduced the treatment into the Monte Carlo simulation, and outputted a traceable and durable dose distribution in the DICOM dose format. MC simulations with TG43-equivalent conditions using both TOPAS andegs_brachyMC codes were compared to TG43 calculations to validate the pipeline. The consistency of the pipeline when generating TG186 simulations was measured by comparing simulations made with both MC codes. Finally,egs_brachysimulations were run on a 240-patient cohort to simulate a large-scale application of the pipeline. Compared to line source TG43 calculations, simulations with both MC codes had more than 90% of voxels with a global difference under ±1%. Differences of 2.1% and less were seen in dosimetric indices when comparing TG186 simulations from both MC codes. The large-scale comparison ofegs_brachysimulations with treatment planning system dose calculation seen the same dose overestimation of TG43 calculations showed in previous studies. The MC dose recalculation pipeline built and validated against TG43 calculations in this work efficiently produced durable MC dose datasets. Since the dataset could reproduce previous dosimetric studies within 15 h at a rate of 20 cases per 25 min, the pipeline is a promising tool for future large-scale dosimetric studies.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Braquiterapia / Radioisótopos do Iodo Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Braquiterapia / Radioisótopos do Iodo Idioma: En Ano de publicação: 2023 Tipo de documento: Article