Diagnostic accuracy of using capnography in verification of nasogastric tube placement among adult patients in hospital settings: Protocol of a diagnostic study.
Chau, Janita Pak Chun; Tong, Danny Wah Kun; Lo, Suzanne Hoi Shan; Sze, Savina Yee Man; Kwok, Molly Lai Mei; Lai, Peter Chi Keung; Lam, Harris Kai Cheong; Chung, Josephine Yuen Man; Liu, Xu; Chien, Wai Tong; Choi, Kai Chow.
Afiliação
  • Chau JPC; Nethersole School of Nursing, The Chinese University of Hong Kong, Hong Kong, Hong Kong.
  • Tong DWK; Nursing Services Department, Hospital Authority Hong Kong, Hong Kong, Hong Kong.
  • Lo SHS; Nethersole School of Nursing, The Chinese University of Hong Kong, Hong Kong, Hong Kong.
  • Sze SYM; Shatin Hospital, Hospital Authority Hong Kong, Hong Kong, Hong Kong.
  • Kwok MLM; Nursing Services Department, Hospital Authority Hong Kong, Hong Kong, Hong Kong.
  • Lai PCK; Queen Mary Hospital, Hospital Authority Hong Kong, Hong Kong, Hong Kong.
  • Lam HKC; Ruttonjee and Tang Shiu Kin Hospitals, Hospital Authority Hong Kong, Hong Kong, Hong Kong.
  • Chung JYM; Prince of Wales Hospital, Hospital Authority Hong Kong, Hong Kong, Hong Kong.
  • Liu X; Nethersole School of Nursing, The Chinese University of Hong Kong, Hong Kong, Hong Kong.
  • Chien WT; Nethersole School of Nursing, The Chinese University of Hong Kong, Hong Kong, Hong Kong.
  • Choi KC; Nethersole School of Nursing, The Chinese University of Hong Kong, Hong Kong, Hong Kong.
PLoS One ; 18(10): e0292667, 2023.
Article em En | MEDLINE | ID: mdl-37871102
ABSTRACT

OBJECTIVE:

To determine the diagnostic accuracy of end-tidal carbon dioxide (ETCO2) detection using capnography for verifying the correct placement of nasogastric tubes (NGTs) among adult patients in hospital settings. MATERIALS AND

METHODS:

A prospective observational diagnostic study will be conducted. Patients ≥ 18-year-old and requiring the insertion of an NGT will be recruited using a convenience sampling method from 39 general medical and geriatric wards, intensive care units, accident and emergency departments, and subacute/rehabilitation/infirmary wards in 21 acute or subacute/convalescent/extended care hospitals. ETCO2 detection by sidestream capnography, which indicates an airway intubation of an NGT when a capnogram waveform or an ETCO2 level > 10mmHg (1.33 kPa) occurs, will serve as the index test. The reference standards will be the X-ray performed and pH value of gastric aspiration (pH ≤ 5.5) after the index test. Each participant will be included only once. Sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve of capnography will be calculated to assess the diagnostic performance of capnography. The variability in diagnostic accuracy in participants with different characteristics will be explored by using chi-squared or Fisher's exact tests. The time spent and the cost of the tests will be compared using the paired t-test. All statistical tests will be two-sided with a level of significance set at 0.05.

DISCUSSION:

This study will provide evidence on the diagnostic accuracy of capnography in verifying NGT placement and its applicability to patients in hospitals settings, since this evidence is limited in the current literature. In addition, it will help identify the optimal combination of tests in verifying the correct placement of NGTs and inform the update of clinical practice guidelines and stakeholders' decisions on the adoption of ETCO2 detection as a routine method for verifying NGT placement. TRIAL REGISTRATION ClinicalTrials.gov ID NCT05817864.