Your browser doesn't support javascript.
loading
Left Atrial-Veno Arterial Extracorporeal Membrane Oxygenation as a Bridge to Surgery for Endocarditis-Related Acute Severe Aortic Regurgitation.
Sabharwal, Aditya; Tsiouris, Athanasios; Slaughter, Mark S; Lemor, Alejandro; Jeyakumar, Ashok Kumar Coimbatore; Protos, Adam; Hernandez, Gabriel A.
Afiliação
  • Sabharwal A; From the Division of Cardiology, University of Mississippi Medical Center, Jackson, Mississippi.
  • Tsiouris A; Division of Cardiac Surgery, University of Mississippi Medical Center, Jackson, Mississippi.
  • Slaughter MS; Department of Cardiovascular and Thoracic Surgery, University of Louisville, Louisville, Kentucky.
  • Lemor A; From the Division of Cardiology, University of Mississippi Medical Center, Jackson, Mississippi.
  • Jeyakumar AKC; Division of Cardiac Surgery, University of Mississippi Medical Center, Jackson, Mississippi.
  • Protos A; Division of Cardiac Surgery, University of Mississippi Medical Center, Jackson, Mississippi.
  • Hernandez GA; From the Division of Cardiology, University of Mississippi Medical Center, Jackson, Mississippi.
ASAIO J ; 70(4): e61-e64, 2024 Apr 01.
Article em En | MEDLINE | ID: mdl-37913501
ABSTRACT
Mechanical circulatory support for cardiogenic shock complicated by acute severe aortic regurgitation poses a unique challenge for traditional veno arterial extracorporeal membrane oxygenation (ECMO) because of rapidly rising left ventricular pressures accentuated by the increased afterload from retrograde flow in femoral cannulation. This process necessitates rapid left ventricular unloading while also allowing for adequate native left ventricular function. Herein, we describe a case of cardiogenic and septic shock secondary to methicillin-resistant Staphylococcus aureus complicated by acute severe aortic regurgitation temporized by left atrial-veno arterial (LA-VA) ECMO via the Livanova TandemHeart system. Left ventricular unloading created a window of hemodynamic stability allowing for optimization of multiorgan failure and infectious source control before surgical aortic valve replacement.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Oxigenação por Membrana Extracorpórea / Staphylococcus aureus Resistente à Meticilina Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Oxigenação por Membrana Extracorpórea / Staphylococcus aureus Resistente à Meticilina Idioma: En Ano de publicação: 2024 Tipo de documento: Article