Your browser doesn't support javascript.
loading
Ultrasound Surveillance is Feasible After Endovascular Aneurysm Repair.
Rakemaa, Lotta; Aho, Pekka S; Tulamo, Riikka; Laine, Matti T; Laukontaus, Sani J; Hakovirta, Harri; Venermo, Maarit.
Afiliação
  • Rakemaa L; Department of Vascular Surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Uusimaa, Finland.
  • Aho PS; Department of Vascular Surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Uusimaa, Finland.
  • Tulamo R; Department of Vascular Surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Uusimaa, Finland.
  • Laine MT; Department of Vascular Surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Uusimaa, Finland.
  • Laukontaus SJ; Department of Vascular Surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Uusimaa, Finland.
  • Hakovirta H; Department of Vascular Surgery, University of Turku and Turku University Hospital, Turku, Varsinais-Suomi, Finland; Department of Surgery, Satasairaala Hospital, Pori, Satakunta, Finland.
  • Venermo M; Department of Vascular Surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Uusimaa, Finland. Electronic address: maarit.venermo@hus.fi.
Ann Vasc Surg ; 100: 223-232, 2024 Mar.
Article em En | MEDLINE | ID: mdl-37926137
ABSTRACT

BACKGROUND:

Surveillance after endovascular aneurysm repair (EVAR) is traditionally done with computed tomography angiography (CTA) scans that exposes patient to radiation, nephrotoxic contrast media, and potentially increased risk for cancer. Ultrasound (US) is less labor intensive and expensive and might thus provide a good alternative for CTA surveillance. The aim of this study was to evaluate in real-life patient cohorts whether US is able to detect post-EVAR aneurysm-related complications similarly to CTA.

METHODS:

This retrospective study compared the outcome of consecutive patients who underwent EVAR for intact abdominal aortic aneurysm and were surveilled solely by CTA (CTA-only cohort, n = 168) in 2000-2010 or by combined CTA and US (CTA/US cohort, n = 300) in 2011-2016, as a standard surveillance protocol in the department of vascular surgery, Helsinki University Hospital. The CTA-only patients were imaged at 1, 3, and 12 months and annually thereafter. The CTA/US patients were imaged with CTA at 3 and 12 months, US at 6 months and annually thereafter. If there were suspicion of >5 mm aneurysm growth, CTA scan was performed. The patients were reviewed for imaging data, reinterventions, aneurysm ruptures, and death until December 2018. The 2 groups were compared for secondary rupture, aneurysm-related and cancer-related death, reintervention related to abdominal aortic aneurysm, and maximum aneurysm diameter increase ≥5 mm. The mean follow-up in the CTA-only cohort was 67 months and in CTA/US cohort 43 months.

RESULTS:

The 2 cohorts were alike for basic characteristics and for the mean aneurysm diameter. The total number of CT scans for detecting aneurysm was 84.1/100 patient years in the CTA-only cohort compared to 74.5/100 patient years for US/CTA cohort. Forty percent of patients under combined CTA/US surveillance received 1 or more additional CTA scans. The 2 cohorts did not differ for 1-year, 5-year and 8-year freedom from aneurysm related death, secondary sac rupture, nor the incidence of rupture preventing interventions.

CONCLUSIONS:

Based on the follow-up data of this real-life cohort of 468 patients, combined surveillance with US and additional CTA either per protocol or due to suspicion of aneurysm-related complications had comparable outcome with sole CTA-surveillance. Thus, US can be considered a reasonable alternative for the CTA. However, our study showed also that the need of additional CTAs due to suspicion of endoleak or aneurysm nonrelated reasons is substantial.