Your browser doesn't support javascript.
loading
Development of in situ crosslinked hyaluronan as an adjunct to vitrectomy surgery.
Suzuki, Kiyoshi; Watanabe, Ippei; Tachibana, Takashi; Mori, Kenichiro; Ishikawa, Keijiro; Ishibashi, Tatsuro; Uchio, Eiichi; Sonoda, Koh-Hei; Hisatomi, Toshio.
Afiliação
  • Suzuki K; Central Research Laboratories, Seikagaku Corporation, 1253, Tateno 3-chome, Higashiyamato-shi, Tokyo, 207-0021, Japan.
  • Watanabe I; Central Research Laboratories, Seikagaku Corporation, 1253, Tateno 3-chome, Higashiyamato-shi, Tokyo, 207-0021, Japan.
  • Tachibana T; Medical Affairs, Seikagaku Corporation, 1-6-1 Marunouchi, Chiyoda-ku, Tokyo, 100-0005, Japan.
  • Mori K; Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Ishikawa K; Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Ishibashi T; Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Uchio E; Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Sonoda KH; Department of Ophthalmology, Faculty of Medicine, Fukuoka University, 8-19-1, Nanakuma, Fukuoka Jonan-ku, Fukuoka, 814-080, Japan.
  • Hisatomi T; Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
J Mater Sci Mater Med ; 34(11): 56, 2023 Nov 06.
Article em En | MEDLINE | ID: mdl-37930485
Ophthalmologists have used hyaluronan (HA) products as adjuncts to ocular surgery since the 1970s. However, HA products are not always functional in surgeries of the posterior eye segment due to their lack of biomechanical strength. In this study, we developed an in situ crosslinked HA (XL-HA) and evaluated its potential as an adjunct to vitrectomy surgery in an in vitro model with a triamcinolone acetonide (TA) layer used as a pseudo residual vitreous cortex (RVC). Within a few minutes at concentrations over 0.9%, XL-HA, generated by the click chemistry of HA-dibenzocyclooctyne and HA-azidoethylamine, formed a hydrogel with the appropriate hardness for tweezers peeling. XL-HA (concentration, 0.76-1.73%) without dispersion successfully entered the TA layer and removed more than 45% of the total TA. Dynamic viscoelasticity helps to explain the rheological behavior of hydrogels, and the assessment results for XL-HA indicated that suitable concentrations were between 0.97% and 1.30%. For example, 1.30% XL-HA hydrogel reached sufficient hardness at 3 min for tweezers peeling, and the TA removal ability exceeded 70%. These results demonstrated that XL-HA was a potential adjunct to successful vitrectomy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oftalmologia / Ácido Hialurônico Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oftalmologia / Ácido Hialurônico Idioma: En Ano de publicação: 2023 Tipo de documento: Article