Your browser doesn't support javascript.
loading
Reproducibility of subscapularis muscle thickness measurement using ultrasound imaging. -Relationship between subscapularis muscle thickness and internal rotation torque of the shoulder joint.
Homma, Hisashi; Aoki, Mitsuhiro; Okino, Kumiko; Hayashi, Tomoya; Yamane, Masahiro; Sasaki, Yuji.
Afiliação
  • Homma H; Graduate School of Rehabilitation Sciences, Health Sciences University of Hokkaido, 1757 Kanazawa, Tobetsu-cho, Ishikari-gun, 061-0293, Hokkaido, Japan; Department of Rehabilitation, Sapporo Hachiken Orthopedic Clinic, Hokkaido, Japan. Electronic address: h2.isashiomma@gmail.com.
  • Aoki M; Graduate School of Rehabilitation Sciences, Health Sciences University of Hokkaido, 1757 Kanazawa, Tobetsu-cho, Ishikari-gun, 061-0293, Hokkaido, Japan. Electronic address: mitsuhiro-ao@hoku-iryo-u.ac.jp.
  • Okino K; Graduate School of Rehabilitation Sciences, Health Sciences University of Hokkaido, 1757 Kanazawa, Tobetsu-cho, Ishikari-gun, 061-0293, Hokkaido, Japan. Electronic address: gokumi5109350421@yahoo.co.jp.
  • Hayashi T; Graduate School of Rehabilitation Sciences, Health Sciences University of Hokkaido, 1757 Kanazawa, Tobetsu-cho, Ishikari-gun, 061-0293, Hokkaido, Japan. Electronic address: haya.19951106@gmail.com.
  • Yamane M; Graduate School of Rehabilitation Sciences, Health Sciences University of Hokkaido, 1757 Kanazawa, Tobetsu-cho, Ishikari-gun, 061-0293, Hokkaido, Japan. Electronic address: yamane.m06@gmail.com.
  • Sasaki Y; Graduate School of Rehabilitation Sciences, Health Sciences University of Hokkaido, 1757 Kanazawa, Tobetsu-cho, Ishikari-gun, 061-0293, Hokkaido, Japan. Electronic address: y-sasaki@hoku-iryo-u.ac.jp.
J Bodyw Mov Ther ; 36: 349-356, 2023 10.
Article em En | MEDLINE | ID: mdl-37949583
BACKGROUND: Few studies have reported on the morphometry of the subscapularis muscle using ultrasound imaging (USI); and their reproducibility has not been verified. OBJECTIVES: This study aimed to clarify the relative and absolute reproducibility of USI measurements of subscapularis muscle thickness at rest and during isometric contraction as well as the degree of change in muscle thickness caused by the amount of internal rotational torque in the shoulder joint. DESIGN: Two-group repeated-measures study. METHODS: The subjects were the inferior fibers of the subscapularis muscle of 40 healthy adult males. Muscle thickness was measured at rest and at 10%-30% of the maximum isometric internal rotation torque. Intraclass correlation coefficients (ICC) and Brand Altman analysis were used for reproducibility measurement. The degree of change in muscle thickness at each torque was also calculated. RESULTS: Intra- and inter-rater ICCs (ranged from 0.69 to 0.91) were good. A proportional error was observed in intra-rater measurements. Both minimal detectable change 95 (ranged from 2.33 to 6.47) were high. The subscapularis muscle thickness was significantly increased at 10% torque (25.49 ± 3.80 mm), 20% torque (26.07 ± 3.90 mm), and 30% torque (25.96 ± 3.82 mm) as compared to that in resting conditions (24.53 ± 4.46 mm) (p < 0.05). CONCLUSION: The reproducibility and error of the subscapularis muscle thickness measurement using USI used in this study were clarified when repeated measurements were made in the same limb position and under the same probe installation conditions, suggesting that the contraction of the subscapularis muscle can be estimated by muscle thickness measurement.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Articulação do Ombro Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Articulação do Ombro Idioma: En Ano de publicação: 2023 Tipo de documento: Article