Your browser doesn't support javascript.
loading
Accelerometer vs. other activity measures in heart failure with preserved ejection fraction: the VITALITY-HFpEF trial.
Butler, Javed; Khan, Muhammad Shahzeb; Gasior, Tomasz; Erickson, Tyler R; Vlajnic, Vanja; Kramer, Frank; Blaustein, Robert O; Goldsbury, David; Roessig, Lothar; Lam, Carolyn S P; Anstrom, Kevin J; Armstrong, Paul W.
Afiliação
  • Butler J; Baylor Scott and White Research Institute, Dallas, TX, USA.
  • Khan MS; University of Mississippi Medical Center, Jackson, MS, USA.
  • Gasior T; Duke Clinical Research Institute, Duke University School of Medicine, Durham, NC, USA.
  • Erickson TR; Boehringer Ingelheim International GmbH, Ingelheim, Germany.
  • Vlajnic V; Duke Clinical Research Institute, Duke University School of Medicine, Durham, NC, USA.
  • Kramer F; Bayer US LLC, Whippany, NJ, USA.
  • Blaustein RO; Bayer AG, Wuppertal, Germany.
  • Goldsbury D; Merck & Co., Inc., Rahway, NJ, USA.
  • Roessig L; Bayer PLC, Reading, UK.
  • Lam CSP; Bayer AG, Wuppertal, Germany.
  • Anstrom KJ; National Heart Centre Singapore and Duke-National University of Singapore, Singapore.
  • Armstrong PW; University of North Carolina, Chapel Hill, NC, USA.
ESC Heart Fail ; 11(1): 293-298, 2024 Feb.
Article em En | MEDLINE | ID: mdl-37985002
ABSTRACT

AIMS:

The relationship between accelerometry data and changes in Kansas City Cardiomyopathy Questionnaire-Physical Limitation Score (KCCQ-PLS) or 6 min walk test (6MWT) is not well understood. METHODS AND

RESULTS:

VITALITY-HFpEF accelerometry substudy (n = 69) data were assessed at baseline and 24 weeks. Ordinal logistic regression models were used to assess the association between accelerometry activity and deterioration, improved, or unchanged KCCQ-PLS (≥8.33 and ≤ -4.17 points) and 6MWT (≥32 vs. ≤ -32 m). KCCQ-PLS score deteriorated in 16 patients, improved in 34, and was unchanged in 19. 6MWT deteriorated in 8 patients, improved in 21, and was unchanged in 19. Mean accelerometer wear was 21.4 (±2.1) h/day. Changes in hours active from baseline to 24 weeks were not significantly different among patients who exhibited deterioration, improvement, or no change in KCCQ-PLS [odds ratio (OR) 0.91, 95% confidence interval (CI) 0.71-1.18; P = 0.48] or 6MWT (OR 1.21, 95% CI 0.91-1.60; P = 0.18). Similar lack of association was observed for other accelerometry metrics and change in KCCQ and 6MWT. These findings were unaffected when KCCQ and 6MWT were examined as continuous variables.

CONCLUSIONS:

Accelerometer-based activity measures did not correlate with subjective or objective standard measures of health status and functional capacity in heart failure with preserved ejection fraction. Further investigation of their relationships to clinical outcomes is required.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência Cardíaca Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência Cardíaca Idioma: En Ano de publicação: 2024 Tipo de documento: Article