Your browser doesn't support javascript.
loading
A combined frequency domain near infrared spectroscopy and diffuse correlation spectroscopy system for comprehensive metabolic monitoring of inspiratory muscles during loading.
Gómez, Carlos A; Brochard, Laurent; Goligher, Ewan C; Rozenberg, Dmitry; Reid, W Darlene; Roblyer, Darren.
Afiliação
  • Gómez CA; Department of Biomedical Engineering, Boston University, Boston, MA 02125, USA.
  • Brochard L; Keenan Research Centre, Li Ka Shing Knowledge Institute, St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada.
  • Goligher EC; Department of Critical Care, St. Michael's Hospital, Toronto, ON, Canada.
  • Rozenberg D; Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, ON, Canada.
  • Reid WD; Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, ON, Canada.
  • Roblyer D; Toronto General Hospital Research Institute, University Health Network, Toronto, ON, Canada.
bioRxiv ; 2023 Dec 01.
Article em En | MEDLINE | ID: mdl-38076980
ABSTRACT

Significance:

Mechanical ventilation (MV) is a cornerstone technology in the intensive care unit as it assists with the delivery of oxygen in critical ill patients. The process of weaning patients from MV can be long, and arduous and can lead to serious complications for many patients. Despite the known importance of inspiratory muscle function in the success of weaning, current clinical standards do not include direct monitoring of these muscles.

Aim:

The goal of this project was to develop and validate a combined frequency domain near infrared spectroscopy (FD-NIRS) and diffuse correlation spectroscopy (DCS) system for the noninvasive characterization of inspiratory muscle response to a load.

Approach:

The system was fabricated by combining a custom digital FD-NIRS and DCS system. It was validated via liquid phantom titrations and a healthy volunteer study. The sternocleidomastoid (SCM), an accessory muscle of inspiration, was monitored during a short loading period in fourteen young healthy volunteer. Volunteers performed two different respiratory exercises, a moderate and high load, which consisted of a one-minute baseline, a one-minute load, and a six-minute recovery period.

Results:

The system has low crosstalk between absorption, reduced scattering, and flow when tested in a set of liquid titrations. Faster dynamics were observed for changes in blood flow index (BFi), and metabolic rate of oxygen (MRO2) compared to hemoglobin + myoglobin (Hb+Mb) based parameters after the onset of loads in males. Additionally, larger percent changes in BFi, and MRO2 were observed compared to Hb+Mb parameters in both males and females. There were also sex differences in baseline values of oxygenated Hb+Mb, total Hb+Mb, and tissue saturation.

Conclusion:

The dynamic characteristics of Hb+Mb concentration and blood flow were distinct during loading of the SCM, suggesting that the combination of FD-NIRS and DCS may provide a more complete picture of inspiratory muscle dynamics.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article