Your browser doesn't support javascript.
loading
Assessment of inhalation exposure to microplastic particles when disposable masks are repeatedly used.
Soo, Jhy-Charm; Wei, Chun-Hsuan; Chen, Jen-Kun; Dong, Guo-Chung; Liu, Zhen-Shu; Chou, Hsiu-Chuan; Perez, Rocio L; Adhikari, Atin; Chen, Yu-Cheng.
Afiliação
  • Soo JC; Department of Biostatistics, Epidemiology and Environmental Health Sciences, Jiann-Ping Hsu College Public Health, Georgia Southern University, Statesboro, GA 30460, USA.
  • Wei CH; National Institute of Environmental Health Sciences, National Health Research Institutes, Miaoli, Taiwan.
  • Chen JK; Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan.
  • Dong GC; Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan.
  • Liu ZS; Department of Safety, Health and Environmental Engineering, Ming Chi University of Technology, New Taipei City, Taiwan.
  • Chou HC; Institute of Analytical and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan.
  • Perez RL; Department of Chemistry, Biochemistry and Physics, College of Science and Mathematics, Georgia Southern University, Statesboro, GA 30460, USA.
  • Adhikari A; Department of Biostatistics, Epidemiology and Environmental Health Sciences, Jiann-Ping Hsu College Public Health, Georgia Southern University, Statesboro, GA 30460, USA.
  • Chen YC; National Institute of Environmental Health Sciences, National Health Research Institutes, Miaoli, Taiwan; Department of Occupational Safety and Health, China Medical University, 91 Hsueh-Shih Road, Taichung, Taiwan; Department of Safety, Health and Environmental Engineering, National United Universi
Sci Total Environ ; 912: 169428, 2024 Feb 20.
Article em En | MEDLINE | ID: mdl-38104815
ABSTRACT
Wearing masks to prevent infectious diseases, especially during the COVID-19 pandemic, is common. However, concerns arise about inhalation exposure to microplastics (MPs) when disposable masks are improperly reused. In this study, we assessed whether disposable masks release inhalable MPs when reused in simulated wearing conditions. All experiments were conducted using a controlled test chamber setup with a constant inspiratory flow. Commercially available medical masks with a three-layer material, composition comprising polypropylene (PP in the outer and middle layers) and polyethylene (PE in the inner layer), were used as the test material. Brand-new masks with and without hand rubbing, as well as reused medical masks, were tested. Physical properties (number, size, and shape) and chemical composition (polymers) were identified using various analytical techniques such as fluorescence staining, fluorescence microscopy, and micro-Fourier Transform Infrared SpectroscopyFTIR). Scanning Electron Microscopy (SEM) was used to scrutinize the surface structure of reused masks across different layers, elucidating the mechanism behind the MP generation. The findings revealed that brand-new masks subjected to hand rubbing exhibited a higher cumulative count of MPs, averaging approximately 1.5 times more than those without hand rubbing. Fragments remained the predominant shape across all selected size classes among the released MPs from reused masks, primarily through a physical abrasion mechanism, accounting for >90 % of the total MPs. The numbers of PE particles were higher than PP particles, indicating that the inner layer of the mask contributed more inhalable MPs than the middle and outer layers combined. The released MPs from reused masks reached their peak after 8 h of wearing. This implies that regularly replacing masks serves as a preventive measure and mitigates associated health risks of inhalation exposure to MPs.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Exposição por Inalação Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Exposição por Inalação Idioma: En Ano de publicação: 2024 Tipo de documento: Article