Your browser doesn't support javascript.
loading
Feasibility of Implementing Patient-Reported and Physical Performance Measures to Identify and Manage Fall Risk in Older Adults Within a Secondary Fracture Clinic.
Bullock, Garrett S; Duncan, Pamela; McMurtrie, Emily; Henry, Kaitlin; Graves, Benjamin F; Lake, Anne R; McDonough, Christine M.
Afiliação
  • Bullock GS; Department of Orthopaedic Surgery, Wake Forest University School of Medicine, Winston-Salem, NC, USA.
  • Duncan P; Department of Biostatistics and Data Science, Wake Forest University School of Medicine, Winston-Salem, NC, USA.
  • McMurtrie E; Department of Neurology, Wake Forest University School of Medicine, Winston-Salem, NC, USA.
  • Henry K; Department of Orthopaedic Surgery, Wake Forest University School of Medicine, Winston-Salem, NC, USA.
  • Graves BF; Department of Orthopaedic Surgery, Wake Forest University School of Medicine, Winston-Salem, NC, USA.
  • Lake AR; Chicago Medical School, Rosalind Franklin University, Chicago, IL, USA.
  • McDonough CM; Department of Orthopaedic Surgery, Wake Forest University School of Medicine, Winston-Salem, NC, USA.
J Appl Gerontol ; 43(6): 745-754, 2024 06.
Article em En | MEDLINE | ID: mdl-38113230
ABSTRACT
The purpose of this study was to assess the feasibility of implementing both electronic and in-person assessments to assess falls risk in an older adult secondary fracture clinic. Electronic data capture feasibility was defined as the proportion of patients that completed the electronic questionnaires prior to their clinic visit. In-clinic feasibility was defined in two ways (1) the proportion of patients that consented to participate at their clinic visit; (2) time to complete testing. Patients were contacted electronically through their health system portal for electronic consent. Patients were invited to complete consent, the STopping Elderly Accidents, Deaths, and Injuries (STEADI) falls risk assessment tool, and the visual analog scale (VAS) for pain. The Short Physical Performance Battery (SPPB) was performed at the clinic visit. A total of 310 patients were contacted electronically. No patients (0%) provided consent through their health portal. Of the 310 patients, 200 (65%) consented in person (Ineligible 67 [21%]; Declined 43 [14%]), resulting in an 82% response rate. In-person data collection took a median of 38.48 (Range 12.34-54.30) minutes to complete. It was not feasible to contact and collect older adult patient data electronically prior to clinic; but, was feasible to obtain these patient-reported outcomes and physical performance data in person.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Acidentes por Quedas / Avaliação Geriátrica / Estudos de Viabilidade Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Acidentes por Quedas / Avaliação Geriátrica / Estudos de Viabilidade Idioma: En Ano de publicação: 2024 Tipo de documento: Article