Your browser doesn't support javascript.
loading
Development and evaluation of an online monitoring single-particle optical particle counter with polarization detection.
Yao, Weijie; Pan, Xiaole; Tian, Yu; Liu, Hang; Zhang, Yuting; Lei, Shandong; Zhang, Junbo; Zhang, Yinzhou; Wu, Lin; Sun, Yele; Wang, Zifa.
Afiliação
  • Yao W; State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Pan X; State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China. Electronic address: panxiaole@mail.iap.ac.cn.
  • Tian Y; State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China.
  • Liu H; State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China.
  • Zhang Y; State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Lei S; State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Zhang J; State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Zhang Y; State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Wu L; State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Sun Y; State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Wang Z; State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China; Center for Excellence
J Environ Sci (China) ; 138: 585-596, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38135422
ABSTRACT
We developed a single-particle optical particle counter with polarization detection (SOPC) for the real-time measurement of the optical size and depolarization ratio (defined as the ratio of the vertical component to the parallel component of backward scattering) of atmospheric particles, the polarization ratio (DR) value can reflect the irregularity of the particles. The SOPC can detect aerosol particles with size larger than 500 nm and the maximum particle count rate reaches ∼1.8 × 105 particles per liter. The SOPC uses a modulated polarization laser to measure the optical size of particles according to forward scattering signal and the DR value of the particles by backward S and P signal components. The sampling rate of the SOPC was 106 #/(sec·channel), and all the raw data were processed online. The calibration curve was obtained by polystyrene latex spheres with sizes of 0.5-10 µm, and the average relative deviation of measurement was 3.96% for sub 3 µm particles. T-matrix method calculations showed that the DR value of backscatter light at 120° could describe the variations in the aspect ratio of particles in the above size range. We performed insitu observations for the evaluation of the SOPC, the mass concentration constructed by the SOPC showed good agreement with the PM2.5 measurements in a nearby state-controlled monitoring site. This instrument could provide useful data for source appointment and regulations against air pollution.