Face Mask and Tear Film Stability: A Pilot Study of the Objective Measurement of Tear Break-Up Time.
Mohamed-Noriega, Karim; Charles-Cantu, David E; Mohamed-Noriega, Jibran; Velasco-Sepúlveda, Braulio H; Morales-Wong, Fernando; Villarreal-Méndez, Gerardo; Mohamed-Hamsho, Jesús.
Afiliação
  • Mohamed-Noriega K; Department of Ophthalmology, University Hospital and Faculty of Medicine, Autonomous University of Nuevo León (UANL), Avenida Francisco I Madero 3501 y Avenida José Eleuterio González (Gonzalitos) S/N, Colonia Mitras Centro, Monterrey 64460, Nuevo León, Mexico.
  • Charles-Cantu DE; Department of Ophthalmology, University Hospital and Faculty of Medicine, Autonomous University of Nuevo León (UANL), Avenida Francisco I Madero 3501 y Avenida José Eleuterio González (Gonzalitos) S/N, Colonia Mitras Centro, Monterrey 64460, Nuevo León, Mexico.
  • Mohamed-Noriega J; Department of Ophthalmology, University Hospital and Faculty of Medicine, Autonomous University of Nuevo León (UANL), Avenida Francisco I Madero 3501 y Avenida José Eleuterio González (Gonzalitos) S/N, Colonia Mitras Centro, Monterrey 64460, Nuevo León, Mexico.
  • Velasco-Sepúlveda BH; Department of Ophthalmology, University Hospital and Faculty of Medicine, Autonomous University of Nuevo León (UANL), Avenida Francisco I Madero 3501 y Avenida José Eleuterio González (Gonzalitos) S/N, Colonia Mitras Centro, Monterrey 64460, Nuevo León, Mexico.
  • Morales-Wong F; Department of Ophthalmology, University Hospital and Faculty of Medicine, Autonomous University of Nuevo León (UANL), Avenida Francisco I Madero 3501 y Avenida José Eleuterio González (Gonzalitos) S/N, Colonia Mitras Centro, Monterrey 64460, Nuevo León, Mexico.
  • Villarreal-Méndez G; Department of Ophthalmology, University Hospital and Faculty of Medicine, Autonomous University of Nuevo León (UANL), Avenida Francisco I Madero 3501 y Avenida José Eleuterio González (Gonzalitos) S/N, Colonia Mitras Centro, Monterrey 64460, Nuevo León, Mexico.
  • Mohamed-Hamsho J; Department of Ophthalmology, University Hospital and Faculty of Medicine, Autonomous University of Nuevo León (UANL), Avenida Francisco I Madero 3501 y Avenida José Eleuterio González (Gonzalitos) S/N, Colonia Mitras Centro, Monterrey 64460, Nuevo León, Mexico.
J Clin Med ; 12(24)2023 Dec 16.
Article em En | MEDLINE | ID: mdl-38137796
ABSTRACT
(1)

Background:

Mask-associated dry eye (MADE) has been associated with increased dry eye symptoms, apparently due to reduced tear break-up time (TBUT). This study aimed to determine the short-term impact of surgical face mask (FM) on tear film stability by measuring non-invasive tear break-up time (NIBUT). (2)

Methods:

Twenty-six healthy participants had NIBUT evaluated without FM, with surgical FM and with a surgical FM secured to the skin with adhesive tape (TFM). NIBUT-first was measured with Keratograph 5M (K5M, Oculus, Wetzlar, Germany). Each participant had NIBUT measured in four sessions on four consecutive days. Session 1 without FM vs. with FM. Session 2 with FM vs. without FM. Session 3 without FM vs. with TFM. Session 4 with TFM vs. without FM (3). The time between each measured setting was 2 min.

Results:

The mean ± SD NIBUT without FM was 8.9 ± 3.7, with FM 10.2 ± 4.1, and with TFM 8.4 ± 3.8 s. No significant differences were observed in NIBUT in any of the evaluated settings without FM vs. with FM (p = 0.247), without FM vs. with TFM (p = 0.915), and with FM vs. with TFM (p = 0.11). (4)

Conclusions:

This study did not find a significant short-term effect of FM on NIBUT. Other variables or longer periods of exposure might trigger the symptoms and ocular surface alterations in MADE.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article