Your browser doesn't support javascript.
loading
Robotic Frameless Stereotactic Aspiration with Thrombolysis for Primary Pontine Hemorrhage: A Therapeutic Evaluation of a Retrospective Cohort Study.
Xu, Chongxi; He, Wenbo; Yi, Tong; Zhang, Hongtian; Xu, Jianguo; Ma, Junpeng.
Afiliação
  • Xu C; Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
  • He W; Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
  • Yi T; Department of Neurology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
  • Zhang H; Department of Neurosurgery, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.
  • Xu J; The affiliated Bayi Brain Hospital, The 7th Medical Center, PLA General Hospital, Beijing, China.
  • Ma J; Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
Article em En | MEDLINE | ID: mdl-38151032
ABSTRACT

BACKGROUND:

There is still no consensus on whether primary pontine hemorrhage (PPH) should be managed conservatively or treated promptly via surgical evacuation of the hematoma. The purpose of this study was to assess the therapeutic effect of robotic frameless stereotactic aspiration with thrombolysis in the treatment of PPH.

METHODS:

A total of 39 patients with PPH treated between January 2012 and November 2016 were included in the study. Sixteen patients underwent frameless stereotactic surgical treatment (ST group) and 23 patients underwent conservative treatment (CT group). Clinical and radiologic parameters were assessed, and the patient outcomes were analyzed over a 6-month follow-up period.

RESULTS:

Surgical treatment did not result in any intracranial infections, or complications. Baseline characteristics did not significantly differ between the two groups. At discharge, the average Glasgow Coma Scale (GCS) score and the overall Glasgow Outcome Scale (GOS) score were significantly higher in the ST group compared to the CT group (p < 0.05). The mortality rate (GOS score 1) was significantly lower in the ST group (18.75%, 3/16) than in the CT group (52.17%, 12/23). For patients with hematoma volumes of 5 to 10 mL or GCS scores of 6 to 8, following treatment, the ST group exhibited markedly higher GOS scores in comparison to the CT group.

CONCLUSION:

Our study suggests that robotic frameless stereotactic aspiration with thrombolysis is a safe and efficient method for the treatment of PPH. Patients with hematomas of 5 to 10 mL or GCS scores of 6 to 8 could benefit from surgery.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article