Deep learning approach using SPECT-to-PET translation for attenuation correction in CT-less myocardial perfusion SPECT imaging.
Ann Nucl Med
; 38(3): 199-209, 2024 Mar.
Article
em En
| MEDLINE
| ID: mdl-38151588
ABSTRACT
OBJECTIVE:
Deep learning approaches have attracted attention for improving the scoring accuracy in computed tomography-less single photon emission computed tomography (SPECT). In this study, we proposed a novel deep learning approach referring to positron emission tomography (PET). The aims of this study were to analyze the agreement of representative voxel values and perfusion scores of SPECT-to-PET translation model-generated SPECT (SPECTSPT) against PET in 17 segments according to the American Heart Association (AHA).METHODS:
This retrospective study evaluated the patient-to-patient stress, resting SPECT, and PET datasets of 71 patients. The SPECTSPT generation model was trained (stress 979 image pairs, rest 987 image pairs) and validated (stress 421 image pairs, rest 425 image pairs) using 31 cases of SPECT and PET image pairs using an image-to-image translation network. Forty of 71 cases of left ventricular base-to-apex short-axis images were translated to SPECTSPT in the stress and resting state (stress 1830 images, rest 1856 images). Representative voxel values of SPECT and SPECTSPT in the 17 AHA segments against PET were compared. The stress, resting, and difference scores of 40 cases of SPECT and SPECTSPT were also compared in each of the 17 segments.RESULTS:
For AHA 17-segment-wise analysis, stressed SPECT but not SPECTSPT voxel values showed significant error from PET at basal anterior regions (segments #1, #6), and at mid inferoseptal regions (segments #8, #9, and #10). SPECT, but not SPECTSPT, voxel values at resting state showed significant error at basal anterior regions (segments #1, #2, and #6), and at mid inferior regions (segments #8, #9, and #11). Significant SPECT overscoring was observed against PET in basal-to-apical inferior regions (segments #4, #10, and #15) during stress. No significant overscoring was observed in SPECTSPT at stress, and only moderate over and underscoring in the basal inferior region (segment #4) was found in the resting and difference states.CONCLUSIONS:
Our PET-supervised deep learning model is a new approach to correct well-known inferior wall attenuation in SPECT myocardial perfusion imaging. As standalone SPECT systems are used worldwide, the SPECTSPT generation model may be applied as a low-cost and practical clinical tool that provides powerful auxiliary information for the diagnosis of myocardial blood flow.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Imagem de Perfusão do Miocárdio
/
Aprendizado Profundo
Idioma:
En
Ano de publicação:
2024
Tipo de documento:
Article