Your browser doesn't support javascript.
loading
Development of competitive and noncompetitive lateral flow immunoassays for pendimethalin using synthetic peptides.
Huang, Lianrun; Wang, Guixiu; Wu, Yanling; Wang, Zhijia; Ding, Yuan; Liang, Hongwu; Hua, Xiude.
Afiliação
  • Huang L; College of Plant Protection, Nanjing Agricultural University, Nanjing, 210095, China.
  • Wang G; State & Local Joint Engineering Research Center of Green Pesticide Invention and Application, Nanjing, 210095, China.
  • Wu Y; College of Plant Protection, Nanjing Agricultural University, Nanjing, 210095, China.
  • Wang Z; State & Local Joint Engineering Research Center of Green Pesticide Invention and Application, Nanjing, 210095, China.
  • Ding Y; College of Plant Protection, Nanjing Agricultural University, Nanjing, 210095, China.
  • Liang H; State & Local Joint Engineering Research Center of Green Pesticide Invention and Application, Nanjing, 210095, China.
  • Hua X; College of Plant Protection, Nanjing Agricultural University, Nanjing, 210095, China.
Mikrochim Acta ; 191(1): 68, 2023 12 30.
Article em En | MEDLINE | ID: mdl-38159155
ABSTRACT
Peptidomimetic and anti-immunocomplex peptides can be easily isolated from phage display libraries, and can be used as alternatives to chemical competing haptens to improve the sensitivity of small molecule immunoassay. In this work, 16 peptidomimetics and 7 anti-immunocomplex peptides of pendimethalin (PND) were obtained from cyclic 7-, 8-, 9-, and 10-residue peptide phage libraries. Peptidomimetic EJ-2 (CMFTGTDFPC) with the highest sensitivity in competitive phage enzyme-linked immunosorbent assay (ELISA) and immunocomplex peptide EF-30 (CNPGWPPIPC) with the highest sensitivity in noncompetitive phage ELISA were selected to prepare phage-free peptides with GGGSSK-biotin at the C-terminus. Competitive and noncompetitive lateral flow immunoassays (CLFIA and NLFIA) were developed by using the phage-free peptides. After optimization, the CLFIA and NLFIA showed visual limit of detections (vLODs) of 5 ng/mL and 2.5 ng/mL, respectively, which were improved two- and fourfold compared with a LFIA based on chemical hapten. The NLFIA showed better sensitivity than CLFIA in the detection of spiked samples, and can meet the detection requirements for agro-products regulated by EU and China. The detection results of CLFIA and NLFIA for blind samples were consistent with that of ultra performance liquid chromatography/tandem mass spectrometry.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bacteriófagos / Peptidomiméticos Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bacteriófagos / Peptidomiméticos Idioma: En Ano de publicação: 2023 Tipo de documento: Article