Your browser doesn't support javascript.
loading
Continuous real-time assessment of acute cognitive stress from cardiac mechanical signals captured by a skin-like patch.
Zavanelli, Nathan; Lee, Sung Hoon; Guess, Matthew; Yeo, Woon-Hong.
Afiliação
  • Zavanelli N; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30024, USA; IEN Center for Wearable Intelligent Systems and Healthcare at the Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA, 30332, USA.
  • Lee SH; IEN Center for Wearable Intelligent Systems and Healthcare at the Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA, 30332, USA; School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA.
  • Guess M; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30024, USA; IEN Center for Wearable Intelligent Systems and Healthcare at the Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA, 30332, USA.
  • Yeo WH; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30024, USA; IEN Center for Wearable Intelligent Systems and Healthcare at the Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA, 30332, USA; Wallace H. Coulter
Biosens Bioelectron ; 248: 115983, 2024 Mar 15.
Article em En | MEDLINE | ID: mdl-38163399
ABSTRACT
The inability to objectively quantify cognitive stress in real-time with wearable devices is a crucial unsolved problem with serious negative consequences for dementia and mental disability patients and those seeking to improve their quality of life. Here, we introduce a skin-like, wireless sternal patch that captures changes in cardiac mechanics due to stress manifesting in the seismocardiogram (SCG) signals. Judicious optimization of the device's micro-structured interconnections and elastomer integration yields a device that sufficiently matches the skin's mechanics, robustly yet gently adheres to the skin without aggressive tapes, and captures planar and longitudinal SCG waves well. The device transmits SCG beats in real-time to a user's device, where derived features relate to the heartbeat's mechanical morphology. The signals are assessed by a series of features in a support vector machine regressor. Controlled studies, compared to gold standard cortisol and following the validated imaging test, show an R-squared correlation of 0.79 between the stress prediction and cortisol change, significantly improving over prior works. Likewise, the system demonstrates excellent robustness to external temperature and physical recovery status while showing excellent accuracy and wearability in full-day use.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hidrocortisona / Técnicas Biossensoriais Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hidrocortisona / Técnicas Biossensoriais Idioma: En Ano de publicação: 2024 Tipo de documento: Article