Use of a modified microvascular plug to modify fenestration flow in a rapidly failing Fontan.
McCay, Nicola; Roberts, Philip; Walsh, Kevin.
Afiliação
  • McCay N; Children's Health Ireland, Dublin, Ireland.
  • Roberts P; Children's Health Ireland, Dublin, Ireland.
  • Walsh K; Children's Health Ireland, Dublin, Ireland.
Cardiol Young ; 34(3): 698-700, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38224016
ABSTRACT
We report a case of an alternative transcatheter use of the modified Medtronic microvascular plug to modify fenestration stent flow in a patient with a rapidly deteriorating clinical condition. This four-year-old boy developed severe cyanosis following fenestration stent insertion, initially placed due to prolonged drainage post-Fontan with extra-cardiac conduit. In April 2023, he underwent urgent cardiac catheterisation and had partial occlusion of fenestration stent with a modified 9Q microvascular plug. His oxygen saturations improved from 50 to 89% in room air with no re-emergence of raised cavopulmonary pressures.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnica de Fontan Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnica de Fontan Idioma: En Ano de publicação: 2024 Tipo de documento: Article