Your browser doesn't support javascript.
loading
Diagnostic performance of 3D automated breast ultrasound (3D-ABUS) in a clinical screening setting-a retrospective study.
Klein Wolterink, Femke; Ab Mumin, Nazimah; Appelman, Linda; Derks-Rekers, Monique; Imhof-Tas, Mechli; Lardenoije, Susanne; van der Leest, Marloes; Mann, Ritse M.
Afiliação
  • Klein Wolterink F; Department of Imaging, Radboud University Medical Center, Geert Grooteplein 10, P.O. Box 9101 (667), 6500 HB, Nijmegen, The Netherlands.
  • Ab Mumin N; Department of Radiology, Faculty of Medicine, University Teknologi MARA, Selangor, Malaysia.
  • Appelman L; Department of Radiology, Alexander Monro Hospital, Bilthoven, The Netherlands.
  • Derks-Rekers M; Department of Imaging, Radboud University Medical Center, Geert Grooteplein 10, P.O. Box 9101 (667), 6500 HB, Nijmegen, The Netherlands.
  • Imhof-Tas M; Department of Imaging, Radboud University Medical Center, Geert Grooteplein 10, P.O. Box 9101 (667), 6500 HB, Nijmegen, The Netherlands.
  • Lardenoije S; Department of Imaging, Radboud University Medical Center, Geert Grooteplein 10, P.O. Box 9101 (667), 6500 HB, Nijmegen, The Netherlands.
  • van der Leest M; Department of Imaging, Radboud University Medical Center, Geert Grooteplein 10, P.O. Box 9101 (667), 6500 HB, Nijmegen, The Netherlands.
  • Mann RM; Department of Imaging, Radboud University Medical Center, Geert Grooteplein 10, P.O. Box 9101 (667), 6500 HB, Nijmegen, The Netherlands. ritse.mann@radboudumc.nl.
Eur Radiol ; 34(8): 5451-5460, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38240805
ABSTRACT

OBJECTIVES:

To assess the diagnostic performance of 3D automated breast ultrasound (3D-ABUS) in breast cancer screening in a clinical setting. MATERIALS AND

METHODS:

All patients who had 3D-ABUS between January 2014 and January 2022 for screening were included in this retrospective study. The images were reported by 1 of 6 breast radiologists based on the Breast Imaging Reporting and Data Systems (BI-RADS). The 3D-ABUS was reviewed together with the digital breast tomosynthesis (DBT). Recall rate, biopsy rate, positive predictive value (PPV) and cancer detection yield were calculated.

RESULTS:

In total, 3616 studies were performed in 1555 women (breast density C/D 95.5% (n = 3455/3616), breast density A/B 4.0% (n = 144/3616), density unknown (0.5% (n = 17/3616)). A total of 259 lesions were detected on 3D-ABUS (87.6% (n = 227/259) masses and 12.4% (n = 32/259) architectural distortions). The recall rate was 5.2% (n = 188/3616) (CI 4.5-6.0%) with only 36.7% (n = 69/188) cases recalled to another date. Moreover, recall declined over time. There were 3.4% (n = 123/3616) biopsies performed, with 52.8% (n = 65/123) biopsies due to an abnormality detected in 3D-ABUS alone. Ten of 65 lesions were malignant, resulting in a positive predictive value (PPV) of 15.4% (n = 10/65) (CI 7.6-26.5%)). The cancer detection yield of 3D-ABUS is 2.77 per 1000 screening tests (CI 1.30-5.1).

CONCLUSION:

The cancer detection yield of 3D-ABUS in a real clinical screening setting is comparable to the results reported in previous prospective studies, with lower recall and biopsy rates. 3D-ABUS also may be an alternative for screening when mammography is not possible or declined. CLINICAL RELEVANCE STATEMENT 3D automated breast ultrasound screening performance in a clinical setting is comparable to previous prospective studies, with better recall and biopsy rates. KEY POINTS • 3D automated breast ultrasound is a reliable and reproducible tool that provides a three-dimensional representation of the breast and allows image visualisation in axial, coronal and sagittal. • The diagnostic performance of 3D automated breast ultrasound in a real clinical setting is comparable to its performance in previously published prospective studies, with improved recall and biopsy rates. • 3D automated breast ultrasound is a useful adjunct to mammography in dense breasts and may be an alternative for screening when mammography is not possible or declined.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Ultrassonografia Mamária / Imageamento Tridimensional Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Ultrassonografia Mamária / Imageamento Tridimensional Idioma: En Ano de publicação: 2024 Tipo de documento: Article