Disruption of a three-component solution as a novel strategy for Cu and Ni extraction from vegetable oils for their determination by GF AAS.
Trevelin, Alex M; Vinhal, Jonas O; Viana, Laís N; Saint'Pierre, Tatiana D; Cassella, Ricardo J.
Afiliação
  • Trevelin AM; Departamento de Química Analítica, Universidade Federal Fluminense, Outeiro de São João Batista s/n, Centro, Niterói, RJ 24020-141, Brazil.
  • Vinhal JO; Instituto Federal de Educação, Ciência e Tecnologia do Maranhão (IFMA), Campus Açailândia, Avenida Projetada, s/n, Vila Progresso II, Açailândia, MA 65930-000, Brazil.
  • Viana LN; Departamento de Química, Pontifícia Universidade Católica do Rio de Janeiro, Rua Marquês de São Vicente 225, Gávea, Rio de Janeiro, RJ 22451-900, Brazil.
  • Saint'Pierre TD; Departamento de Química, Pontifícia Universidade Católica do Rio de Janeiro, Rua Marquês de São Vicente 225, Gávea, Rio de Janeiro, RJ 22451-900, Brazil.
  • Cassella RJ; Departamento de Química Analítica, Universidade Federal Fluminense, Outeiro de São João Batista s/n, Centro, Niterói, RJ 24020-141, Brazil. Electronic address: rcassella@id.uff.br.
Food Chem ; 442: 138492, 2024 Jun 01.
Article em En | MEDLINE | ID: mdl-38245986
ABSTRACT
In this work, we propose a novel approach for extracting Cu and Ni from vegetable oils (which can be expanded to other metals). The method is based on the transference of the analytes to an aqueous acid phase due to the disruption of a three-component solution. The extraction was carried out in two steps. In the first step, a three-component solution was prepared comprising the sample, 1-octanol, and HNO3 solution. Next, the homogeneous system was disrupted by adding 1.0 mL of deionized water, and two phases were formed. The aqueous extract deposited in the bottom of the flask was collected with a micropipette, and Cu and Ni were determined by graphite furnace atomic absorption spectrometry (GF AAS). The developed method presented limits of quantification (LOQ) of 0.25 and 0.17 ng g-1 for Cu and Ni, respectively, and was successfully applied in the analysis of eleven oil samples from different origins.