Your browser doesn't support javascript.
loading
Fast Determination of Rutin on a Biosensor Made Using a Layered Double Hydroxide Nanocomposite Modified Electrode.
Liu, Yuge; Li, Zhiguo; Chen, Weizhen; Feng, Xiaomiao.
Afiliação
  • Liu Y; Key Laboratory of Clean Energy Materials Chemistry of Guangdong Higher Education Institutes, School of Chemistry and Chemical Engineering, Lingnan Normal University, Zhanjiang 524048, China.
  • Li Z; Key Laboratory of Clean Energy Materials Chemistry of Guangdong Higher Education Institutes, School of Chemistry and Chemical Engineering, Lingnan Normal University, Zhanjiang 524048, China.
  • Chen W; Key Laboratory of Clean Energy Materials Chemistry of Guangdong Higher Education Institutes, School of Chemistry and Chemical Engineering, Lingnan Normal University, Zhanjiang 524048, China.
  • Feng X; Key Laboratory for Organic Electronics and Information Displays, Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications, Nanjing 210023, China.
Biosensors (Basel) ; 14(1)2023 Dec 29.
Article em En | MEDLINE | ID: mdl-38248395
ABSTRACT
In this study, a nanocomposite of LDH/graphene/polyaniline/gold (LDH/rGO/PANI/Au) was synthesized and characterized. The results of characterization showed that the composite material preserved the layered structure of LDH. The composite was dropped onto the glassy carbon electrode and laccase was then immobilized. Electrochemical tests showed that the composite could accelerate the electron transfer between the enzyme and the electrode. The composite/laccase showed an obvious response to rutin and the optimal detection conditions were discussed. The oxidative peak current of the biosensor constructed using the modified electrode was negatively correlated with rutin in the range of 0.05-4 µg/mL. The detection limit was 0.0017 µg/mL at a signal-to-noise ratio of 3. This biosensor of rutin also possessed high sensitivity, excellent anti-interference ability, and stability. The contents of rutin in tablets, first determined using HPLC, were also detected using the sensor constructed in this research as an application, and the results were acceptable. This research here provides a facile way for the fast detection of rutin in real samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanocompostos Idioma: En Ano de publicação: 2023 Tipo de documento: Article