Effect of Lens Status on the Outcomes of Glaucoma Drainage Device Implantation.
Stallworth, Jeannette Y; Hekmatjah, Natan; Yu, Yinxi; Oatts, Julius T; Ying, Gui-Shuang; Han, Ying.
Afiliação
  • Stallworth JY; Department of Ophthalmology, University of California, San Francisco, San Francisco, California.
  • Hekmatjah N; School of Medicine, University of California, San Francisco, San Francisco, California.
  • Yu Y; Scheie Eye Institute, Center for Preventive Ophthalmology and Biostatistics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania.
  • Oatts JT; Department of Ophthalmology, University of California, San Francisco, San Francisco, California.
  • Ying GS; Scheie Eye Institute, Center for Preventive Ophthalmology and Biostatistics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania.
  • Han Y; Department of Ophthalmology, University of California, San Francisco, San Francisco, California. Electronic address: ying.han@ucsf.edu.
Ophthalmol Glaucoma ; 7(3): 242-250, 2024.
Article em En | MEDLINE | ID: mdl-38278362
ABSTRACT

PURPOSE:

To assess the effect of lens status and cataract surgery on glaucoma drainage device (GDD) efficacy.

DESIGN:

Retrospective cohort study.

PARTICIPANTS:

Two hundred and forty-three eyes of 216 patients that underwent GDD implantation with ≥1 follow-up visit within 3 years postoperatively. Exclusion criteria included GDD combined with other ophthalmic procedures. 90%-94% of GDDs were Ahmed implants; 83%-90% had adjunctive mitomycin-C.

METHODS:

Outcomes were compared between phakic eyes (group A), eyes phakic at time of implantation but subsequently underwent cataract surgery within 3 years (group B), and pseudophakic eyes (group C). Outcomes were measured at 1, 3, 6, 12, 24, and 36 months after tube shunt implantation. Multivariable regression models were performed, adjusting for baseline characteristics. MAIN OUTCOME

MEASURES:

Intraocular pressure (IOP) after GDD implantation. Secondary outcomes included change in visual acuity (VA), number of glaucoma eye drops, and rate of failure, defined as additional glaucoma surgery, vision decrease to no light perception, or IOP persistently ≤ 5 mmHg or > 21 mmHg or not reduced from baseline by 20%.

RESULTS:

There were 65 eyes in group A, 52 in group B, and 126 in group C. Within group B, cataract surgery was performed at a mean of 1.3 ± 0.7 years after GDD implantation. There were no statistically significant differences in mean IOP or medications between the 3 groups at all time points up to 3 years postoperatively. Significant improvement in VA was noted in groups A and B compared to group C at 6 months, 1 year, and 2 years after implantation; however, by postoperative year 3, change in VA was similar across groups. There were no significant differences in the failure rate amongst groups (P = 0.68). IOP and medications up to 12 months after cataract surgery were similar compared to preoperative baseline. Group B had significantly more short-term (P = 0.02) and long-term (P < 0.001) postoperative complications than groups A or C, driven primarily by hypotony.

CONCLUSIONS:

There were no differences in IOP, glaucoma medications, or rate of failure 3 years after GDD implantation based on lens status or after undergoing subsequent cataract surgery. These results may inform the management of patients with co-existing glaucoma and cataract. FINANCIAL DISCLOSURE(S) The author(s) have no proprietary or commercial interest in any materials discussed in this article.