Your browser doesn't support javascript.
loading
Compressed sensing with deep learning reconstruction: Improving capability of gadolinium-EOB-enhanced 3D T1WI.
Nagata, Hiroyuki; Ohno, Yoshiharu; Yoshikawa, Takeshi; Yamamoto, Kaori; Shinohara, Maiko; Ikedo, Masato; Yui, Masao; Matsuyama, Takahiro; Takahashi, Tomoki; Bando, Shuji; Furuta, Minami; Ueda, Takahiro; Ozawa, Yoshiyuki; Toyama, Hiroshi.
Afiliação
  • Nagata H; Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan.
  • Ohno Y; Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan; Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan. Electronic address: yohno@fujita-hu.ac.jp.
  • Yoshikawa T; Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan; Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan; Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Hyogo, 673-0021, J
  • Yamamoto K; Canon Medical Systems Corporation, Otawara, Tochigi, 324-8550, Japan.
  • Shinohara M; Canon Medical Systems Corporation, Otawara, Tochigi, 324-8550, Japan.
  • Ikedo M; Canon Medical Systems Corporation, Otawara, Tochigi, 324-8550, Japan.
  • Yui M; Canon Medical Systems Corporation, Otawara, Tochigi, 324-8550, Japan.
  • Matsuyama T; Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan.
  • Takahashi T; Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan.
  • Bando S; Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan.
  • Furuta M; Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan.
  • Ueda T; Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan.
  • Ozawa Y; Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan.
  • Toyama H; Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan.
Magn Reson Imaging ; 108: 67-76, 2024 May.
Article em En | MEDLINE | ID: mdl-38309378
ABSTRACT

PURPOSE:

The purpose of this study was to determine the utility of compressed sensing (CS) with deep learning reconstruction (DLR) for improving spatial resolution, image quality and focal liver lesion detection on high-resolution contrast-enhanced T1-weighted imaging (HR-CE-T1WI) obtained by CS with DLR as compared with conventional CE-T1WI with parallel imaging (PI).

METHODS:

Seventy-seven participants with focal liver lesions underwent conventional CE-T1WI with PI and HR-CE-T1WI, surgical resection, transarterial chemoembolization, and radiofrequency ablation, followed by histopathological or >2-year follow-up examinations in our hospital. Signal-to-noise ratios (SNRs) of liver, spleen and kidney were calculated for each patient, after which each SNR was compared by means of paired t-test. To compare focal lesion detection capabilities of the two methods, a 5-point visual scoring system was adopted for a per lesion basis analysis. Jackknife free-response receiver operating characteristic (JAFROC) analysis was then performed, while sensitivity and false positive rates (/data set) for consensus assessment of the two methods were also compared by using McNemar's test or the signed rank test.

RESULTS:

Each SNR of HR-CE-T1WI was significantly higher than that of conventional CE-T1WI with PI (p < 0.05). Sensitivities for consensus assessment showed that HR-CE-MRI had significantly higher sensitivity than conventional CE-T1WI with PI (p = 0.004). Moreover, there were significantly fewer FP/cases for HR-CE-T1WI than for conventional CE-T1WI with PI (p = 0.04).

CONCLUSION:

CS with DLR are useful for improving spatial resolution, image quality and focal liver lesion detection capability of Gd-EOB-DTPA enhanced 3D T1WI without any need for longer breath-holding time.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Quimioembolização Terapêutica / Carcinoma Hepatocelular / Aprendizado Profundo / Neoplasias Hepáticas Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Quimioembolização Terapêutica / Carcinoma Hepatocelular / Aprendizado Profundo / Neoplasias Hepáticas Idioma: En Ano de publicação: 2024 Tipo de documento: Article