Your browser doesn't support javascript.
loading
Application of a combined cancellous lag screw enhances the stability of locking plate fixation of osteoporotic lateral tibial plateau fracture by providing interfragmentary compression force.
Jiang, Jiang; Xu, Daqiang; Ji, Zhenhua; Wang, Fei; Jia, Rui; Wang, Jun; Hong, Hong; Zhang, Hongtao; Li, Jianyi.
Afiliação
  • Jiang J; Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual and Reality Experimental Education Center for Medical Morphology, School of Basic Medical Scienc
  • Xu D; Department of Orthopedics, Affiliated Hospital 6 of Nantong University, Yancheng Third People's Hospital, Yancheng, China.
  • Ji Z; Department of Rehabilitation Medicine, Shandong Public Health Clinical Center, Shandong University, Jinan, China.
  • Wang F; Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual and Reality Experimental Education Center for Medical Morphology, School of Basic Medical Scienc
  • Jia R; Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual and Reality Experimental Education Center for Medical Morphology, School of Basic Medical Scienc
  • Wang J; Department of Rehabilitation Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China.
  • Hong H; Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual and Reality Experimental Education Center for Medical Morphology, School of Basic Medical Scienc
  • Zhang H; Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual and Reality Experimental Education Center for Medical Morphology, School of Basic Medical Scienc
  • Li J; Zhongshan Torch Development Zone People's Hospital, No.123, Yixian Road, Torch Development District, Zhongshan, 528437, Guangdong, China. femur@163.com.
J Orthop Surg Res ; 19(1): 139, 2024 Feb 14.
Article em En | MEDLINE | ID: mdl-38351078
ABSTRACT

BACKGROUND:

Insufficient interfragmentary compression force (IFCF) frequently leads to unstable fixation of osteoporotic lateral tibial plateau fractures (OLTPFs). A combined cancellous lag screw (CCLS) enhances IFCF; however, its effect on OLTPF fixation stability remains unclear. Therefore, we investigated the effect of CCLS on OLTPF stability using locking plate fixation (LPF). MATERIALS AND

METHODS:

Twelve synthetic osteoporotic tibial bones were used to simulate OLTPFs, which were fixed using LPF, LPF-AO cancellous lag screws (LPF-AOCLS), and LPF-CCLS. Subsequently, 10,000 cyclic loadings from 30 to 400 N were performed. The initial axial stiffness (IAS), maximal axial micromotion of the lateral fragment (MAM-LF) measured every 1000 cycles, and failure load after 10,000 cycles were tested. The same three fixations for OLTPF were simulated using finite element analysis (FEA). IFCFs of 0, 225, and 300 N were applied to the LPF, LPF-AOCLS, and LPF-CCLS, respectively, with a 1000-N axial compressive force. The MAM-LF, peak von Mises stress (VMS), peak equivalent elastic strain of the lateral fragment (EES-LF), and nodes of EES-LF > 2% (considered bone destruction) were calculated.

RESULTS:

Biomechanical tests revealed the LPF-AOCLS and LPF-CCLS groups to be superior to the LPF group in terms of the IAS, MAM-LF, and failure load (all p < 0.05). FEA revealed that the MAM-LF, peak VMS, peak EES-LF, and nodes with EES-LF > 2% in the LPF were higher than those in the LPF-AOCLS and LPF-CCLS.

CONCLUSION:

IFCF was shown to enhance the stability of OLTPFs using LPF. Considering overscrewing, CCLS is preferably recommended, although there were no significant differences between CCLS and AOCLS.